+ | After converging, the fitted value of Q2 is 0.1778619910379541. The original value of Q2 was 0.1828815622086947 (from section '' | ||
+ | This is a (0.1828815622086947 - 0.1778619910379541) / (0.1828815622086947) * 100 = 2.74% decrease. This almost compensates for the 3% increase in the effective field length. | ||
+ | |||
+ | **Problem 8** | ||
+ | |||
+ | The mass resolutions of '' | ||
+ | In order to have a 5% decrease in the mass resolutions, | ||
+ | (60.123-x)/ | ||
+ | |||
+ | The beam position (offsetting the optical axis) can be changed with the '' |