Line 27: Line 27:
  
 {{ :dipole46cr13.png?400 |}} {{ :dipole46cr13.png?400 |}}
 +
  
 **Emittance measurement**\\ **Emittance measurement**\\
 Distance between Q7 center and focal plane is 6.085 m. Distance between Q7 center and focal plane is 6.085 m.
 +{{ :emittance.png?400 |}}
 +
 +Q7 strenght variation:\\
 +|B [T] |Xmax[m] |ap [m] |Brho [Tm] |L [m] |K|
 +|0.02 |2.91E-03 |0.13 |0.8 |0.34 |0.065384615|
 +|0.01 |2.27E-03 |0.13 |0.8 |0.34 |0.032692308|
 +|0 |1.62E-03 |0.13 |0.8 |0.34 |0|
 +|-0.01 |1.20E-03 |0.13 |0.8 |0.34 |-0.032692308|
 +|-0.02 |9.08E-04 |0.13 |0.8 |0.34 |-0.065384615|
 +|-0.03 |6.23E-04 |0.13 |0.8 |0.34 |-0.098076923|
 +|-0.04 |9.54E-04 |0.13 |0.8 |0.34 |-0.130769231|
 +|-0.05 |1.60E-03 |0.13 |0.8 |0.34 |-0.163461538|
 +|-0.06 |2.26E-03 |0.13 |0.8 |0.34 |-0.196153846|\\
 +
 +**Fit of the data to parabola**
 +{{ :plot.png?400 |}}
 +
 +a = 0.000362572706 \\
 +b = 0.0834414129893 \\
 +c = 3.506973286e-07\\
 +double check for beam size calculation in Q7: X_calculated = X_cosy_read_out = 3.55
 +Emittance = 3.045387898578198e-07  π m rad= 0.3 π mm mrad
 +start beam emittance= XX * AX= 0.2 π mm mrad so the emittance grows from the start to the focal point
  
/srv/thewikis/JIOSS/data/pages/group_secar2.0.txt · Last modified: 2018/09/13 16:49 by plastun