 +**DAY1 
 +**
 Reaction: <sup>45</sup>V(p,γ)<sup>46</sup>Cr\\ Reaction: <sup>45</sup>V(p,γ)<sup>46</sup>Cr\\
 Beam: <sup>45</sup>V<sup>13+</sup> of 135 MeV (1% enegry spread)\\ Beam: <sup>45</sup>V<sup>13+</sup> of 135 MeV (1% enegry spread)\\
Line 28: Line 30:
 {{ :dipole46cr13.png?400 |}} {{ :dipole46cr13.png?400 |}}
  
 +**DAY2**
 **Emittance measurement**\\ **Emittance measurement**\\
 Distance between Q7 center and focal plane is 6.085 m. Distance between Q7 center and focal plane is 6.085 m.
Line 54: Line 56:
 Emittance = 3.045387898578198e-07  π m rad= 0.3 π mm mrad\\ Emittance = 3.045387898578198e-07  π m rad= 0.3 π mm mrad\\
 start beam emittance= XX * AX= 0.2 π mm mrad so the emittance grows from the start to the focal point\\ start beam emittance= XX * AX= 0.2 π mm mrad so the emittance grows from the start to the focal point\\
 +Emittance grows due to the optics aberrations. Input COSY file shows 4th-order-calculation. Also measured points don't fit the parabola ideally, i.e. optics is non-linear.\\
 +
  
/srv/thewikis/JIOSS/data/pages/group_secar2.0.txt · Last modified: 2018/09/13 16:49 by plastun