 c = 3.506973286e-07\\ c = 3.506973286e-07\\
 Double check for beam size calculation in Q7: X_calculated = 3.13mm, X_cosy_read_out = 3.16mm at the Q7 exit.\\ Double check for beam size calculation in Q7: X_calculated = 3.13mm, X_cosy_read_out = 3.16mm at the Q7 exit.\\
-Emittance = 3.045387898578198e-07  π m rad= 0.3 π mm mrad\\ +Emittance = 3.045387898578198e-07  π m rad= 0.3 π mm mrad.\\ 
-start beam emittance= XX * AX= 0.2 π mm mrad so the emittance grows from the start to the focal point\\ +Start beam emittance= XX * AX= 0.2 π mm mradso the emittance grows from the start to the focal point.\\ 
-Emittance grows due to the optics aberrations. Input COSY file shows 4th-order-calculation. Also measured points don't fit the parabola ideally, i.e. optics is non-linear.\\+This rmittance grow is possibly due to the optics aberrations. Input COSY file does a 4th-order-calculation. Also the measured points don't fit the parabola ideally, i.e. optics is non-linear.\\
  
  