group_secar2.0 [2018/09/11 16:50] wagner |
group_secar2.0 [2018/09/11 16:52] wagner |
||
---|---|---|---|
Line 71: | Line 71: | ||
c = 3.506973286e-07\\ | c = 3.506973286e-07\\ | ||
- | The consistency check for beam size calculation in Q7 shows: X_calculated = 3.13mm, X_cosy_read_out = 3.16mm at the Q7 exit.\\ | + | The consistency check for beam size calculation in Q7 shows:\\ |
+ | X_calculated = 3.13mm, X_cosy_read_out = 3.16mm at the Q7 exit.\\ | ||
Emittance calculated from fit parameter | Emittance calculated from fit parameter | ||
Start beam emittance= XX * AX= 0.2 π mm mrad, so the emittance grows from the start to the focal point.\\ | Start beam emittance= XX * AX= 0.2 π mm mrad, so the emittance grows from the start to the focal point.\\ |