Line 71: Line 71:
 c = 3.506973286e-07\\ c = 3.506973286e-07\\
  
-The consistency check for beam size calculation in Q7 shows: X_calculated = 3.13mm, X_cosy_read_out = 3.16mm at the Q7 exit.\\+The consistency check for beam size calculation in Q7 shows:\\ 
 +X_calculated = 3.13mm, X_cosy_read_out = 3.16mm at the Q7 exit.\\
 Emittance calculated from fit parameter  = 3.045387898578198e-07  π m rad= 0.3 π mm mrad.\\ Emittance calculated from fit parameter  = 3.045387898578198e-07  π m rad= 0.3 π mm mrad.\\
 Start beam emittance= XX * AX= 0.2 π mm mrad, so the emittance grows from the start to the focal point.\\ Start beam emittance= XX * AX= 0.2 π mm mrad, so the emittance grows from the start to the focal point.\\