group_secar2.0 [2018/09/11 17:23]
wagner [Emittance Measurement]
group_secar2.0 [2018/09/11 17:23]
wagner [Emittance Measurement]
Line 73: Line 73:
 The consistency check for beam size calculation in Q7 shows:\\ The consistency check for beam size calculation in Q7 shows:\\
 X_calculated = 3.13mm, X_cosy_read_out = 3.16mm at the Q7 exit.\\ X_calculated = 3.13mm, X_cosy_read_out = 3.16mm at the Q7 exit.\\
-Emittance calculated from fit parameters ε= √(ac) / L<sup>2</sup> = 3.05E-7 π m rad = 0.305 π mm mrad.\\ +Emittance calculated from fit parameters ε= √(ac) / L<sup>2</sup> = 3.05E-7 π m rad = **0.305 π mm mrad**.\\ 
-Start beam emittance= XX AX= 0.2 π mm mrad, so the emittance grows from the start to the focal point.\\+Start beam emittance= XX · AX= 0.2 π mm mrad, so the emittance grows from the start to the focal point.\\
 This emittance grow is possibly due to the optics aberrations. That is because the input COSY file does a 4th-order-calculation. Also the measured points don't fit the parabola ideally, i.e. the optics is non-linear.\\ This emittance grow is possibly due to the optics aberrations. That is because the input COSY file does a 4th-order-calculation. Also the measured points don't fit the parabola ideally, i.e. the optics is non-linear.\\
  
  
/srv/thewikis/JIOSS/data/pages/group_secar2.0.txt · Last modified: 2018/09/13 16:49 by plastun