User Tools

Site Tools


group_secar2.0

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
group_secar2.0 [2018/09/13 14:31]
plastun
group_secar2.0 [2018/09/13 15:05]
plastun
Line 28: Line 28:
 {{ :reaction_kinematics.png?400 |}} {{ :reaction_kinematics.png?400 |}}
  
-Reaction summary for <sup>45</sup>V+p→γ+<sup>46</sup>Cr, E<sub>kin</sub>(<sup>45</sup>V)=135 MeV\\+Reaction summary for <sup>45</sup>V+p → γ+<sup>46</sup>Cr, E<sub>kin</sub>(<sup>45</sup>V)=135 MeV\\
 The maximum γ energy is 8.481 MeV. The minimum γ energy is 7.249 MeV.\\ The maximum γ energy is 8.481 MeV. The minimum γ energy is 7.249 MeV.\\
 The maximum <sup>46</sup>Cr energy is **132.634 MeV**. The minimum <sup>46</sup>Cr energy is **131.402 MeV**. The maximum <sup>46</sup>Cr angle is **0.13 degrees**.\\ The maximum <sup>46</sup>Cr energy is **132.634 MeV**. The minimum <sup>46</sup>Cr energy is **131.402 MeV**. The maximum <sup>46</sup>Cr angle is **0.13 degrees**.\\
Line 92: Line 92:
 ===== DAY4===== ===== DAY4=====
 ==== Optics misalignments ==== ==== Optics misalignments ====
 +
 +**Beam position. Longitudinal offset.**
  
 We populated "X-θ" phase-space with rays distributed on the border of ellipse by the loop: We populated "X-θ" phase-space with rays distributed on the border of ellipse by the loop:
Line 100: Line 102:
 ENDLOOP;'' ENDLOOP;''
  
-Number of rays in another planes is set to one:+Rays in another planes are on-axis:
  
-''SRYY:= 0.0;\\ +''SRYY:= 0.0; 
-SRAY:= 0.0;\\+SRAY:= 0.0;
 SRDE:= 0.0;'' SRDE:= 0.0;''
  
-Created loop for target position. Observed piece-wise curve for resolution vs target offset (see figure below) in case of 4th order calculation. If order reduced to the 1st, than curve is smooth, but maximum resolution is shifted. +Created loop for target position. Observed piece-wise curve for resolution vs target offset (meters) (see figure below) in case of 4th order calculation. If order reduced to the 1st, than curve is smooth, but maximum resolution is shifted. 
-{{ :target_offset.png?400 |}}+{{ :target_offset.png?450 |}} 
 +The resolution drops by 5% at the offsets (-5 mm, +7 mm).\\ 
 + 
 +**Beam position. Transverse offset.** 
 +{{ :transv.png?450 |}} 
 +The resolution drops by 5% at the beam offsets (-0.8 mm, +0.5 mm). The offset is of the beam half-size order. \\ 
 + 
 +==== Recoil tracking ==== 
 + 
 +**<sup>45</sup>V+p → γ+<sup>46</sup>Cr** 
 + 
 +Beam is set to 132MeV <sup>46</sup>Cr<sup>14+</sup>\\ 
 +''RP 132.0 46*PARA(1) 14*PARA(2) ;''\\ 
 +''{Design acceptances, depends on kinematics of a specific reaction!}\\ 
 +XX:=0.0005;\\ 
 +AX:=0.01726;\\ 
 +YY:=0.0005;\\ 
 +AY:=0.01726;\\ 
 +DE:=0.0047;''
/srv/thewikis/JIOSS/data/pages/group_secar2.0.txt · Last modified: 2018/09/13 16:49 by plastun