User Tools

Site Tools


questions_area

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
questions_area [2018/08/24 21:08]
admin
questions_area [2018/09/12 22:55]
berg
Line 1: Line 1:
-Please share your questions to instructors and fellow participants here+==== Some questions from Lecture 1 (Berg):==== 
 + 
 +  * Why are the dots on the "Diagnostics in focal plane of Spectrometer" so evenly spaced?  
 +  * What is the real world example of measuring emittance?  
 +  * (2) Describe the focal plane diagnostics of the spectrometer in more detail 
 +  * (2) l doesn't appear to have a dependence on anything. Can you clarify how l(t) transforms? How exactly is l define?  
 +  * Can you show a (x|a)!=0 case 
 +  * (4) Why is sigma matrix symmetric? What is definition of sigma_21? How do we create the 6x6 ellipse matrix?  
 +  * How does the x-Theta measurement setup look like (measure orientation of ellipse) 
 +  * Definition of Louisville Theorem?   
 +  * How do we define the central ray?  
 +  * R11, R12, R21, R22 - can more than one be zero?  
 +{{:questions_answers.pdf |Answers}} 
 + 
 +==== Some questions from Lecture 2 (Couder):==== 
 +  * Does the kinematics calculator include anisotropic gamma radiation?  
 +  * Why is the angular acceptance fixed?  
 +  * Beam spot and divergence in front of target, focusing necessary to minimize (x|a)?  
 +  * If (x|a) is non zero, how does that affect the resolving power? 
 +  * Rejection requirements were unclear 
 +  * Is x_0 the half beam spot size?  
 +  * definition of rejection for detectors 
 +  * What is the meaning of the interpolation line of the charge state distribution?  
 +  * Are separators ever compromised by space charge effects from large beam currents?  
 +  * What limits the systematic errors in measurement efficiency, transmission, charge state population?  
 +  * How significant can be the background in a (p,g) experiment from target impurities?  
 +  * Notation: is there a difference between (x|d)d_1, (x,m)dM/M, and (x|\Delta M) \Delta M/M?   
 + 
 +==== Some questions from Lecture 3 (Berg):==== 
 + 
 +  * 1) Does COSY allow implementation of higher order corrections in dipoles? 
 +  * 2) Why dipoles doublets instead of one large dipole? 
 +  * 3) Definition of K, T, and C in dispersion matching. 
 +  * 4) Define fringe field. 
 +  * 5) Define Rogowski profile. 
 +  * 6) Explain H and K coil in K600 Spectrometer. Why quad inside K600? 
 +  * 7) Explain HO in K600 Spectrometer. 
 +  * 8) How to use reconstruct the scattering angle at target from focal plane measurement? Setup of  
 +    multi-slit for angle calibration, drift between target and multi-slit. 
 +  * 9) Discuss only one spectrometer (e.g. K600, Grand Raiden, Big Karl). 
 +  * 10) Explain magnetization of ferro-magnetic material. 
 +  * 11) p. 14 Why not 0 deg with beam (for dispersion matching)? 
 +  * 12) Will permanent magnet saturate material. Similar to coil generated fields? 
 +  * 13) Why is dispersion matching needed? 
 +  * 14) Can EFL be measured? 
 + 
/srv/thewikis/JIOSS/data/pages/questions_area.txt · Last modified: 2018/09/24 13:01 by berg