User Tools

Site Tools


questions_area

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
questions_area [2018/09/10 19:38]
berg
questions_area [2018/09/24 13:01] (current)
berg
Line 1: Line 1:
-Some questions from Lecture 1 (Berg):+==== Some questions from Lecture 1 (Berg):==== 
   * Why are the dots on the "Diagnostics in focal plane of Spectrometer" so evenly spaced?    * Why are the dots on the "Diagnostics in focal plane of Spectrometer" so evenly spaced? 
   * What is the real world example of measuring emittance?    * What is the real world example of measuring emittance? 
Line 10: Line 11:
   * How do we define the central ray?    * How do we define the central ray? 
   * R11, R12, R21, R22 - can more than one be zero?    * R11, R12, R21, R22 - can more than one be zero? 
-{{ :questions_answers.pptx |Answers}}+{{:questions_answers.pdf |Answers}} 
 + 
 +==== Some questions from Lecture 2 (Couder):==== 
 +  * Does the kinematics calculator include anisotropic gamma radiation?  
 +  * Why is the angular acceptance fixed?  
 +  * Beam spot and divergence in front of target, focusing necessary to minimize (x|a)?  
 +  * If (x|a) is non zero, how does that affect the resolving power? 
 +  * Rejection requirements were unclear 
 +  * Is x_0 the half beam spot size?  
 +  * definition of rejection for detectors 
 +  * What is the meaning of the interpolation line of the charge state distribution?  
 +  * Are separators ever compromised by space charge effects from large beam currents?  
 +  * What limits the systematic errors in measurement efficiency, transmission, charge state population?  
 +  * How significant can be the background in a (p,g) experiment from target impurities?  
 +  * Notation: is there a difference between (x|d)d_1, (x,m)dM/M, and (x|\Delta M) \Delta M/M?   
 + 
 +==== Some questions from Lecture 3 (Berg):==== 
 + 
 +  * 1) Does COSY allow implementation of higher order corrections in dipoles? 
 +  * 2) Why dipoles doublets instead of one large dipole? 
 +  * 3) Definition of K, T, and C in dispersion matching. 
 +  * 4) Define fringe field. 
 +  * 5) Define Rogowski profile. 
 +  * 6) Explain H and K coil in K600 Spectrometer. Why quad inside K600? 
 +  * 7) HO in K600 Spectrometer. 
 +  * 8) How to use reconstruct the scattering angle at target from focal plane measurement? Setup of multi-slit for angle calibration, drift between target and multi-slit. 
 +  * 9) Discuss only one spectrometer (e.g. K600, Grand Raiden, Big Karl). 
 +  * 10) Explain magnetization of ferro-magnetic material. 
 +  * 11) p. 14 Why not 0 deg with beam (for dispersion matching)? 
 +  * 12) Will permanent magnet saturate material. Similar to coil generated fields? 
 +  * 13) Why is dispersion matching needed? 
 +  * 14) Can EFL be measured? 
 + 
 +{{ :questions_answers_lecture2.pdf |Answers}} 
 + 
 +==== Some questions from Lecture 4 (Berg):==== 
 + 
 +  * 1) How does COSY calculated the fringe field? 
 +  * 2) How important are accurate fringe field measurements for SECAR and St. GEORGE? 
 +  * 3) What is the meaning of the rectangles in  COSY graphics output? 
 +  * 4) In an achromatic fragment separator, do you need a slit and/or a wedge in the dispersive intermediate plane. 
 +  * 5) In a gas filled separator are all charge states collected in one location? 
 +  * 6) How does a wedge restore the achromaticity in a fragment separator? 
 +  * 7) What is the purpose of the DSR (Spin dipole) in front of GRAND RAIDEN focal plan? 
 +{{ :questions_answers_lecture3.pdf |Answers}} 
 + 
 +==== Some questions from Lecture 5 (Berg):==== 
 + 
 +  * 1) Why are there 189 Characteristic Rays (see Procedure CHARAY)? 
 +  * 2) How realistic is Gaussian distribution for the incoming beam? 
 +  * 3) Difference between dispersive focus and achromatic focus. 
 +  * 4) On ST. GEORGE the reactions that push the energy acceptance (+/-8%) also pushes the angular acceptance (+/-40 mrad). This doesn’t seem to be true in SECAR: 15O(p,g)19Ne pushes the energy acceptance (+/-3.1%) but not in the angular acceptance (only +/-15.6 mradvs. SECAR’s +/-25 mrad acceptance). Is there a reason SECAR was designed with angular acceptance so much larger than the energy acceptance? 
 +  * 5) Purpose of SECAR Section 3? 
 +  * 6) On slide 6, what is the meaning of the arrows the Effective Field Length and Good Field Regions? 
 +  * 7) Extended target for SECAR? 
 +  * 8) Engefunction (not from this Lecture)? 
 +  * 9) Is Q1 (Quad + Hex) used or only a design feature? 
 +  * 10) x_HO= (x’|x)*2_0 + HO, how are the higher order terms (HO) added 
 +  * 11) Clarify D in the definition of the Nominal Beam definition 
 +  * 12) Why is the alignment adjusted before and after the ion optical element? 
 +  * 13) Can the recirculatory-ring for projectile beam increase the nuclear reaction rate? I.E. can we return the projectile beam (passed through the target) to the beam again. 
 +  * 14) Alignment example not clear. 
 +  * 15) Does higher order effects give us details about the initial beam characteristic? Or do HO effects tell us that the beam line is different than what we think? ( e.g. field imperfections in the magnets etc.) 
 +{{ :questions_answers_lecture4.pdf |Answers}}
  
/srv/thewikis/JIOSS/data/attic/questions_area.1536622707.txt.gz · Last modified: 2018/09/10 19:38 by berg