Some questions from Lecture 1 (Berg):

  • Why are the dots on the “Diagnostics in focal plane of Spectrometer” so evenly spaced?
  • What is the real world example of measuring emittance?
  • (2) Describe the focal plane diagnostics of the spectrometer in more detail
  • (2) l doesn't appear to have a dependence on anything. Can you clarify how l(t) transforms? How exactly is l define?
  • Can you show a (x|a)!=0 case
  • (4) Why is sigma matrix symmetric? What is definition of sigma_21? How do we create the 6×6 ellipse matrix?
  • How does the x-Theta measurement setup look like (measure orientation of ellipse)
  • Definition of Louisville Theorem?
  • How do we define the central ray?
  • R11, R12, R21, R22 - can more than one be zero?

Answers

Some questions from Lecture 2 (Couder):

  • Does the kinematics calculator include anisotropic gamma radiation?
  • Why is the angular acceptance fixed?
  • Beam spot and divergence in front of target, focusing necessary to minimize (x|a)?
  • If (x|a) is non zero, how does that affect the resolving power?
  • Rejection requirements were unclear
  • Is x_0 the half beam spot size?
  • definition of rejection for detectors
  • What is the meaning of the interpolation line of the charge state distribution?
  • Are separators ever compromised by space charge effects from large beam currents?
  • What limits the systematic errors in measurement efficiency, transmission, charge state population?
  • How significant can be the background in a (p,g) experiment from target impurities?
  • Notation: is there a difference between (x|d)d_1, (x,m)dM/M, and (x|\Delta M) \Delta M/M?

Some questions from Lecture 3 (Berg):

  • 1) Does COSY allow implementation of higher order corrections in dipoles?
  • 2) Why dipoles doublets instead of one large dipole?
  • 3) Definition of K, T, and C in dispersion matching.
  • 4) Define fringe field.
  • 5) Define Rogowski profile.
  • 6) Explain H and K coil in K600 Spectrometer. Why quad inside K600?
  • 7) HO in K600 Spectrometer.
  • 8) How to use reconstruct the scattering angle at target from focal plane measurement? Setup of multi-slit for angle calibration, drift between target and multi-slit.
  • 9) Discuss only one spectrometer (e.g. K600, Grand Raiden, Big Karl).
  • 10) Explain magnetization of ferro-magnetic material.
  • 11) p. 14 Why not 0 deg with beam (for dispersion matching)?
  • 12) Will permanent magnet saturate material. Similar to coil generated fields?
  • 13) Why is dispersion matching needed?
  • 14) Can EFL be measured?

Answers

/srv/thewikis/JIOSS/data/attic/questions_area.1536807474.txt.gz · Last modified: 2018/09/12 22:57 by berg