 ===== Plastic scintillators ===== ===== Plastic scintillators =====
 In order to determine the Time-Of-Flight for the particle identification, the S800 includes a plastic scintillator at the [[Stations#Object_station|object station]] (S800_OBJ) and at the [[Stations#focal_plane_station|focal-plane station]] (E1). The detector material typically used is  In order to determine the Time-Of-Flight for the particle identification, the S800 includes a plastic scintillator at the [[Stations#Object_station|object station]] (S800_OBJ) and at the [[Stations#focal_plane_station|focal-plane station]] (E1). The detector material typically used is 
-[[http://www.detectors.saint-gobain.com/uploadedFiles/SGdetectors/Documents/Product_Data_Sheets/BC400-404-408-412-416-Data-Sheet.pdf|BC-400]] or [[http://www.detectors.saint-gobain.com/uploadedFiles/SGdetectors/Documents/Product_Data_Sheets/BC400-404-408-412-416-Data-Sheet.pdf|BC-404]] made from polyvinyltoluene (>97% ) and organic fluors  (<3%) with a density 1.032 g/cm<sup>3</sup> and a refractive index 1.58. The thickness of the detectors is chosen on the basis of the charge of the nuclei to be measured. The available thicknesses are __127 μm and 1 mm__ for OBJ_SCI and __1 mm and 5 mm__ for E1.  The OBJ_SCI has an active area of __xxx__ and is connected to a photomultiplier __xxx__. The E1 scintillator is connected to photomultipliers [[EMI 98807B]] in both ends (up and down). The time signal from the E1 scintillator is calculated as the average time signal from each photomultipliers.+[[http://www.detectors.saint-gobain.com/uploadedFiles/SGdetectors/Documents/Product_Data_Sheets/BC400-404-408-412-416-Data-Sheet.pdf|BC-400]] or [[http://www.detectors.saint-gobain.com/uploadedFiles/SGdetectors/Documents/Product_Data_Sheets/BC400-404-408-412-416-Data-Sheet.pdf|BC-404]] made from polyvinyltoluene (>97% ) and organic fluors  (<3%) with a density 1.032 g/cm<sup>3</sup> and a refractive index 1.58. The thickness of the detectors is chosen on the basis of the charge of the nuclei to be measured. The available thicknesses are __127 μm and 1 mm__ for OBJ_SCI and __1 mm and 5 mm__ for E1. (Guidelines explaining the installation of E1 scintillator can be found [[Installation FP SCI|here]]).  The OBJ_SCI has an active area of __xxx__ and is connected to a photomultiplier __xxx__. The E1 scintillator is connected to photomultipliers [[EMI 98807B]] in both ends (up and down). The time signal from the E1 scintillator is calculated as the average time signal from each photomultipliers.
 Different Time-of-flights can be constructed by combining the timing signals from these two detectors with the timing signals from the [[https://groups.nscl.msu.edu/a1900/|A1900]] focal plane, and the RF cyclotron. The E1 detector is also used to define a valid trigger from the S800. The timing resolution for a point-like beam spot in the focal plane is around 100 ps. However, this resolution worsens significantly (up to 1 ns) when the whole focal plane is illuminated, because of path length differences of the traversing nuclei. It can be recovered by tracking the position of each event on the scintillator from the position and angle information provided by the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDC]] detectors. The plastic scintillators can withstand maximum rates up to 1 x 10<sup>6</sup> particles per second. Different Time-of-flights can be constructed by combining the timing signals from these two detectors with the timing signals from the [[https://groups.nscl.msu.edu/a1900/|A1900]] focal plane, and the RF cyclotron. The E1 detector is also used to define a valid trigger from the S800. The timing resolution for a point-like beam spot in the focal plane is around 100 ps. However, this resolution worsens significantly (up to 1 ns) when the whole focal plane is illuminated, because of path length differences of the traversing nuclei. It can be recovered by tracking the position of each event on the scintillator from the position and angle information provided by the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDC]] detectors. The plastic scintillators can withstand maximum rates up to 1 x 10<sup>6</sup> particles per second.
 +
 +
  
  