event_filter [2015/10/30 18:51]
pereira [CRDC packets]
event_filter [2015/10/31 11:30]
pereira [CRDC packets]
Line 3: Line 3:
 The trigger bits words indicates which bits were set during the event. The encoding of the bits is the following: The trigger bits words indicates which bits were set during the event. The encoding of the bits is the following:
  
-In this section, the following diagram will be used to describe a 16-bit word sent by the Filter. The first row includes the value, either in decimal or hexadecimal format, or a descriptive note. The second row shows the value in binary ("X"s are used to describe arbitrary values that vary from event to event). The last row shows the bit number. +In this section, each 16-bit word sent by the Filter is described by a 16x3-table diagram. The first row includes the value, either in decimal or hexadecimal format, or a descriptive note. The second row shows the value in binary ("X"s are used to describe arbitrary values that vary from event to event). The last row shows the bit number. 
  
  
Line 293: Line 293:
   * **Packet Length** (self-inclusive)   * **Packet Length** (self-inclusive)
  
-^    A number from 4 to 18    ^^^^^^^^^^^^^^|+^    A number from 4 to 18    ^^^^^^^^^^^^^^^|
 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | X | X | X | X | X | | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | X | X | X | X | X |
 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Line 381: Line 381:
 The anode energy (encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]]) is given by:  The anode energy (encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]]) is given by: 
  
- ^^^ Ch ^   energy   ^^^^^^^^^^^| +empty ^^^^   energy   ^^^^^^^^^^^| 
-| 0 | 0 | 0 | | X | X | X | X | X | X | X | X | X | X | X | X |+| 0 | 0 | 0 | | X | X | X | X | X | X | X | X | X | X | X | X |
 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
  
Line 390: Line 390:
 The anode time (from an ORTEC TAC encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]]) is given by:  The anode time (from an ORTEC TAC encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]]) is given by: 
  
-^  Empty ^^^^   energy   ^^^^^^^^^^^|+^  empty ^^^^   energy   ^^^^^^^^^^^|
 | 0 | 0 | 0 | 0 | X | X | X | X | X | X | X | X | X | X | X | X | | 0 | 0 | 0 | 0 | X | X | X | X | X | X | X | X | X | X | X | X |
 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |