User Tools

Site Tools


event_filter

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
event_filter [2015/10/31 11:34]
pereira [CRDC packets]
event_filter [2015/10/31 12:20]
pereira [CRDC packets]
Line 293: Line 293:
   * **Packet Length** (self-inclusive)   * **Packet Length** (self-inclusive)
  
-^    A number from to 18    ^^^^^^^^^^^^^^^| +^    A number from 10 to 330    ^^^^^^^^^^^^^^^| 
-| 0 | 0 | 0 | 0 | 0 | 0 | 0 | | X | X | X | X | X |+| 0 | 0 | 0 | 0 | 0 | 0 | 0 | | X | X | X | X | X |
 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
  
Line 318: Line 318:
   * **CRDC Sub-packet "Raw" Length** (self-inclusive)   * **CRDC Sub-packet "Raw" Length** (self-inclusive)
  
-^   A number from to 16    ^^^^^^^^^^^^^^^| +^   A number from to 323    ^^^^^^^^^^^^^^^| 
-| 0 | 0 | 0 | 0 | 0 | 0 | 0 | | X | X | X | X | X |+| 0 | 0 | 0 | 0 | 0 | 0 | 0 | | X | X | X | X | X |
 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
  
Line 390: Line 390:
 The anode time (from an ORTEC TAC encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]]) is given by:  The anode time (from an ORTEC TAC encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]]) is given by: 
  
-^  empty ^^^^   energy   ^^^^^^^^^^^|+^  empty ^^^^   time   ^^^^^^^^^^^|
 | 0 | 0 | 0 | 0 | X | X | X | X | X | X | X | X | X | X | X | X | | 0 | 0 | 0 | 0 | X | X | X | X | X | X | X | X | X | X | X | X |
 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +==== Intermediate-image PPACs packet ====
 +The Filter provides a PPAC packet: one for [[Detectors|Cathode Readout Drift Chambers (CRDC)|CRDC1]] and one for [[Detectors|Cathode Readout Drift Chambers (CRDC)|CRDC2]]. Each CRDC packet is divided in two sub-packets: the "Raw" sub-packet with information about the pads energies (encoded in the [[S800 USB DAQ data format#Tag 0xCFDC: XLM72V crdc1 pad readout module|CRDCs XLM72 modules]]), and the "Anode" sub-packet with anode energy and time information encoded in the CRDCs [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|Phillips ADC]]. In the following, we describe the structure of the packet provided by the Filter for each CRDC.
 +
 +  * **Packet Length** (self-inclusive)
 +
 +^    A number from 10 to 330    ^^^^^^^^^^^^^^^|
 +| 0 | 0 | 0 | 0 | 0 | 0 | 0 | X | X | X | X | X | X | X | X | X |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +
 +  * **Packet Tag**
 +
 +^    0x5840    ^^^^^^^^^^^^^^^|
 +| 0 | 1 | 0 | 1 | 1 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +
 +
 +  * **CRDC label**
 +
 +^    0x0000 or 0x0001   ^^^^^^^^^^^^^^^|
 +| 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | X |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +where 0x0000 and 0x0001 identify CRDC1 and CRDC2, respectively.
 +
 +
 +
 +  * **CRDC Sub-packet "Raw" Length** (self-inclusive)
 +
 +^   A number from 3 to 323    ^^^^^^^^^^^^^^^|
 +| 0 | 0 | 0 | 0 | 0 | 0 | 0 | X | X | X | X | X | X | X | X | X |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +
 +
 +  * **CRDC Sub-packet "Raw" Tag** 
 +
 +^    0x5841    ^^^^^^^^^^^^^^^|
 +| 0 | 1 | 0 | 1 | 1 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 1 |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +
 +
 +  * **Global threshold** 
 +
 +^    0x0000    ^^^^^^^^^^^^^^^|
 +| 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +This word is reserved for a global threshold; it is no longer used, so it is set to 0 
 +
 +
 +
 +  * **Samples sub-packets**
 +The Filter sends a series of sample sub-packets. Each sub-packet consists of two parts. The first part includes one 16-bit word with information about the **sample** and **channel** numbers:
 +
 +^  control bit  ^   sample    ^^^^^^^^^   channel   ^^^^^|
 +| 1 | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +where **channel** is a number between 0 and 63, and refers to a group of four pads. The second part includes __up to four__ consecutive 16-bit words, each with a pad energy __greater than 0__:
 +
 +^  control bit  ^  empty  ^^^  connector  ^^  energy  ^^^^^^^^^|
 +| 0 | 0 | 0 | 0 | X | X | X | X | X | X | X | X | X | X | X | X |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +The **connector** number is related to the pad number (**pad**) according to: **pad** = **channel** + **connector** x 64 (where **connector** ranges from 0 to 3, and **channel** is given by the first word of the sample sub-packet). Note that the Filter processes information from connectors with energies greater than 0. 
 +
 +
 +
 +
 +
 +  * **CRDC Sub-packet "Anode" Length** (self-inclusive)
 +
 +^    4    ^^^^^^^^^^^^^^^|
 +| 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +
 +
 +  * **CRDC Sub-packet "Anode" Tag** 
 +
 +^    0x5845    ^^^^^^^^^^^^^^^|
 +| 0 | 1 | 0 | 1 | 1 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 1 | 0 | 1 |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +
 +
 +
 +  * **Energy from Anode**
 +The anode energy (encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]]) is given by: 
 +
 +^  empty  ^^^^   energy   ^^^^^^^^^^^|
 +| 0 | 0 | 0 | 0 | X | X | X | X | X | X | X | X | X | X | X | X |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
 +
 +
 +  * **Time from Anode**
 +The anode time (from an ORTEC TAC encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]]) is given by: 
 +
 +^  empty ^^^^   time   ^^^^^^^^^^^|
 +| 0 | 0 | 0 | 0 | X | X | X | X | X | X | X | X | X | X | X | X |
 +| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
 +
  
  
event_filter.txt · Last modified: 2019/05/24 13:58 by pereira