event_filter [2016/03/16 15:52] pereira [Event-number packet] |
event_filter [2016/03/16 15:54] pereira [Hodoscope packet] |
||
---|---|---|---|
Line 20: | Line 20: | ||
- | ==== Time-stamp packet ==== | + | ===== Time-stamp packet |
The timestamp is encoded in the [[S800 USB DAQ data format#Tag 0x5803: XLM72 time stamp module|XLMV72 time-stamp module]] for each event as a 64-bit word. The Event Filter parses it as a set of four consecutive 16-bit words. | The timestamp is encoded in the [[S800 USB DAQ data format#Tag 0x5803: XLM72 time stamp module|XLMV72 time-stamp module]] for each event as a 64-bit word. The Event Filter parses it as a set of four consecutive 16-bit words. | ||
Line 110: | Line 110: | ||
- | ==== Trigger packet ==== | + | ===== Trigger packet |
The trigger packet includes a bit-pattern word (encoded | The trigger packet includes a bit-pattern word (encoded | ||
Line 164: | Line 164: | ||
- | ==== Time-of-flight packet ==== | + | ===== Time-of-flight packet |
The time-of-flight packet includes all the timing values encoded in the [[S800 USB DAQ data format#Tag 0x7186: Phillips 7186 TDC module for time-of-flights|Phillips TDC]] and the XFP-FP and OBJ-FP ToF from the ORTEC TACs encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]]. | The time-of-flight packet includes all the timing values encoded in the [[S800 USB DAQ data format#Tag 0x7186: Phillips 7186 TDC module for time-of-flights|Phillips TDC]] and the XFP-FP and OBJ-FP ToF from the ORTEC TACs encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]]. | ||
Line 207: | Line 207: | ||
- | ==== Scintillator packet ==== | + | ===== Scintillator packet |
The scintillator packet includes the energy (encoded in the [[S800 USB DAQ data format#Tag 0x4300: FERA module for plastic scintillator energies|FERA LeCroy module]]) and time (encoded in the [[S800 USB DAQ data format#Tag 0x7186: Phillips 7186 TDC module for time-of-flights|Phillips TDC]]) of the [[Detectors# | The scintillator packet includes the energy (encoded in the [[S800 USB DAQ data format#Tag 0x4300: FERA module for plastic scintillator energies|FERA LeCroy module]]) and time (encoded in the [[S800 USB DAQ data format#Tag 0x7186: Phillips 7186 TDC module for time-of-flights|Phillips TDC]]) of the [[Detectors# | ||
Line 252: | Line 252: | ||
- | ==== Ion-Chamber packet ==== | + | ===== Ion-Chamber packet |
The Ion-chamber packet includes the energies of the [[Detectors# | The Ion-chamber packet includes the energies of the [[Detectors# | ||
Line 301: | Line 301: | ||
- | ==== CRDC packets ==== | + | ===== CRDC packets |
The Filter provides two CRDC packets: one for [[Detectors|Cathode Readout Drift Chambers (CRDC)|CRDC1]] and one for [[Detectors|Cathode Readout Drift Chambers (CRDC)|CRDC2]]. Each CRDC packet is divided in two sub-packets: | The Filter provides two CRDC packets: one for [[Detectors|Cathode Readout Drift Chambers (CRDC)|CRDC1]] and one for [[Detectors|Cathode Readout Drift Chambers (CRDC)|CRDC2]]. Each CRDC packet is divided in two sub-packets: | ||
Line 416: | Line 416: | ||
- | ==== Hodoscope packet ==== | + | ===== Hodoscope packet |
The Filter parses the [[Detectors# | The Filter parses the [[Detectors# | ||
[[S800 USB DAQ data format#Tag 0x7165: Phillips 7164 ADC module for hodoscope energies 0 through 15|Phillips 7164 ADCs]] and re-formats the data in three packets, two with the energies of the two groups crystals (from 1 to 16 and from 17 to 32), and the third one with the hit pattern recorded in the [[S800 USB DAQ data format#Tag 0x4448: LeCroy4448 coincidence register module for hodoscope hit pattern|LeCroy 4448 coincidence-register module]]. | [[S800 USB DAQ data format#Tag 0x7165: Phillips 7164 ADC module for hodoscope energies 0 through 15|Phillips 7164 ADCs]] and re-formats the data in three packets, two with the energies of the two groups crystals (from 1 to 16 and from 17 to 32), and the third one with the hit pattern recorded in the [[S800 USB DAQ data format#Tag 0x4448: LeCroy4448 coincidence register module for hodoscope hit pattern|LeCroy 4448 coincidence-register module]]. |