event_filter [2016/03/16 15:53]
pereira [Trigger packet]
event_filter [2016/03/16 15:53]
pereira [Scintillator packet]
Line 164: Line 164:
  
  
-==== Time-of-flight packet ====+===== Time-of-flight packet =====
 The time-of-flight packet includes all the timing values encoded in the [[S800 USB DAQ data format#Tag 0x7186: Phillips 7186 TDC module for time-of-flights|Phillips TDC]] and the XFP-FP and OBJ-FP ToF from the ORTEC TACs encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]].  The time-of-flight packet includes all the timing values encoded in the [[S800 USB DAQ data format#Tag 0x7186: Phillips 7186 TDC module for time-of-flights|Phillips TDC]] and the XFP-FP and OBJ-FP ToF from the ORTEC TACs encoded in the [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|S800 Phillips 7164H ADC]]. 
  
Line 207: Line 207:
  
  
-==== Scintillator packet ====+===== Scintillator packet =====
 The scintillator packet includes the energy (encoded in the [[S800 USB DAQ data format#Tag 0x4300: FERA module for plastic scintillator energies|FERA LeCroy module]]) and time (encoded in the [[S800 USB DAQ data format#Tag 0x7186: Phillips 7186 TDC module for time-of-flights|Phillips TDC]]) of the [[Detectors#Plastic scintillators|S800 FP scintillator]] signals. In the original configuration, there were 3 scintillators (E1, E2, and E3) which were later reduced to just one (E1) after the installation of the Hodoscope.  The scintillator packet includes the energy (encoded in the [[S800 USB DAQ data format#Tag 0x4300: FERA module for plastic scintillator energies|FERA LeCroy module]]) and time (encoded in the [[S800 USB DAQ data format#Tag 0x7186: Phillips 7186 TDC module for time-of-flights|Phillips TDC]]) of the [[Detectors#Plastic scintillators|S800 FP scintillator]] signals. In the original configuration, there were 3 scintillators (E1, E2, and E3) which were later reduced to just one (E1) after the installation of the Hodoscope. 
  
event_filter.txt ยท Last modified: 2019/05/24 13:58 by pereira