User Tools

Site Tools


event_filter

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
event_filter [2016/03/16 15:53]
pereira [Time-of-flight packet]
event_filter [2016/03/16 15:54]
pereira [Hodoscope packet]
Line 207: Line 207:
  
  
-==== Scintillator packet ====+===== Scintillator packet =====
 The scintillator packet includes the energy (encoded in the [[S800 USB DAQ data format#Tag 0x4300: FERA module for plastic scintillator energies|FERA LeCroy module]]) and time (encoded in the [[S800 USB DAQ data format#Tag 0x7186: Phillips 7186 TDC module for time-of-flights|Phillips TDC]]) of the [[Detectors#Plastic scintillators|S800 FP scintillator]] signals. In the original configuration, there were 3 scintillators (E1, E2, and E3) which were later reduced to just one (E1) after the installation of the Hodoscope.  The scintillator packet includes the energy (encoded in the [[S800 USB DAQ data format#Tag 0x4300: FERA module for plastic scintillator energies|FERA LeCroy module]]) and time (encoded in the [[S800 USB DAQ data format#Tag 0x7186: Phillips 7186 TDC module for time-of-flights|Phillips TDC]]) of the [[Detectors#Plastic scintillators|S800 FP scintillator]] signals. In the original configuration, there were 3 scintillators (E1, E2, and E3) which were later reduced to just one (E1) after the installation of the Hodoscope. 
  
Line 252: Line 252:
  
  
-==== Ion-Chamber packet ====+===== Ion-Chamber packet =====
 The Ion-chamber packet includes the energies of the [[Detectors#Ionization chamber|16 ion-chamber segments]] encoded in one of the [[S800 USB DAQ data format#Tag 0x7164: Phillips 7164 ADC module for ion chamber energies|Phillips 7164H ADC]]. The Ion-chamber packet includes the energies of the [[Detectors#Ionization chamber|16 ion-chamber segments]] encoded in one of the [[S800 USB DAQ data format#Tag 0x7164: Phillips 7164 ADC module for ion chamber energies|Phillips 7164H ADC]].
  
Line 301: Line 301:
  
  
-==== CRDC packets ====+===== CRDC packets =====
 The Filter provides two CRDC packets: one for [[Detectors|Cathode Readout Drift Chambers (CRDC)|CRDC1]] and one for [[Detectors|Cathode Readout Drift Chambers (CRDC)|CRDC2]]. Each CRDC packet is divided in two sub-packets: the "Raw" sub-packet with information about the pads energies (encoded in the [[S800 USB DAQ data format#Tag 0xCFDC: XLM72V crdc1 pad readout module|CRDCs XLM72 modules]]), and the "Anode" sub-packet with anode energy and time information encoded in the CRDCs [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|Phillips ADC]]. In the following, we describe the structure of the packet provided by the Filter for each CRDC. The Filter provides two CRDC packets: one for [[Detectors|Cathode Readout Drift Chambers (CRDC)|CRDC1]] and one for [[Detectors|Cathode Readout Drift Chambers (CRDC)|CRDC2]]. Each CRDC packet is divided in two sub-packets: the "Raw" sub-packet with information about the pads energies (encoded in the [[S800 USB DAQ data format#Tag 0xCFDC: XLM72V crdc1 pad readout module|CRDCs XLM72 modules]]), and the "Anode" sub-packet with anode energy and time information encoded in the CRDCs [[S800 USB DAQ data format#Tag 0x7167: Phillips 7164 ADC module for CRDC anodes (energies and TAC)|Phillips ADC]]. In the following, we describe the structure of the packet provided by the Filter for each CRDC.
  
Line 416: Line 416:
  
  
-==== Hodoscope packet ====+===== Hodoscope packet =====
 The Filter parses the [[Detectors#Hodoscope|Hodoscope]] information encoded in the two  The Filter parses the [[Detectors#Hodoscope|Hodoscope]] information encoded in the two 
 [[S800 USB DAQ data format#Tag 0x7165: Phillips 7164 ADC module for hodoscope energies 0 through 15|Phillips 7164 ADCs]] and re-formats the data in three packets, two with the energies of the two groups crystals (from 1 to 16 and from 17 to 32), and the third one with the hit pattern recorded in the [[S800 USB DAQ data format#Tag 0x4448: LeCroy4448 coincidence register module for hodoscope hit pattern|LeCroy 4448 coincidence-register module]]. [[S800 USB DAQ data format#Tag 0x7165: Phillips 7164 ADC module for hodoscope energies 0 through 15|Phillips 7164 ADCs]] and re-formats the data in three packets, two with the energies of the two groups crystals (from 1 to 16 and from 17 to 32), and the third one with the hit pattern recorded in the [[S800 USB DAQ data format#Tag 0x4448: LeCroy4448 coincidence register module for hodoscope hit pattern|LeCroy 4448 coincidence-register module]].
event_filter.txt ยท Last modified: 2019/05/24 13:58 by pereira