Line 42: Line 42:
       * Ensure that the gas bottles are not empty       * Ensure that the gas bottles are not empty
            * The gas regulators are not normally adjusted. They should all be set to provide a pressure around 20 psi.            * The gas regulators are not normally adjusted. They should all be set to provide a pressure around 20 psi.
-           * The bottle supplying the P-10 gas for the ion chamber is secured to the cross-brace of the south support for the focal plane chamber.  It has an electronic Ashcroft pressure gauge upstream of the regulator (toggle on and off with the on/off” switch) and a mechanical pressure gauge downstream of the regulator.  +           * The bottle supplying the P-10 gas for the [[Detectors#Ionization Chamber|ionization chamber]] is secured to the cross-brace of the south support for the focal plane chamber. It has an electronic Ashcroft pressure gauge upstream of the regulator (toggle on and off with the "on/offswitch) and a mechanical pressure gauge downstream of the regulator.  
-           * The bottle supplying CF<sub>4</sub> (tetrafluoromethane) gas for the CRDCs is secured to the cross-brace of the south support for the focal plane chamber. It has an electronic Ashcroft pressure gauge upstream of the regulator (toggle on and off with the “on/off” switch) and a mechanical pressure gauge downstream of the regulator.  +           * The bottle supplying CF<sub>4</sub> (tetrafluoromethane) gas for the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDCs]] is secured to the cross-brace of the south support for the focal plane chamber. It has an electronic Ashcroft pressure gauge upstream of the regulator (toggle on and off with the “on/off” switch) and a mechanical pressure gauge downstream of the regulator.  
-           * The bottle supplying isobutane (C<sub>4</sub>H<sub>10</sub>) for the CRDCs is secured to the south support post for the focal plane chamber. It sits on a scale for monitoring the isobutane consumption – the electronic display for the scale sits on the chiller unit under the focal plane chamber. It has a mechanical pressure gauge downstream of the regulator. +           * The bottle supplying isobutane (C<sub>4</sub>H<sub>10</sub>) for the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDCs]] is secured to the south support post for the focal plane chamber. It sits on a scale for monitoring the isobutane consumption – the electronic display for the scale sits on the chiller unit under the focal plane chamber. It has a mechanical pressure gauge downstream of the regulator. 
  
 +{{:wiki:gas-bottle3.jpg?300}}
 +{{:wiki:gas-bottle1.jpg?300}}
  