User Tools

Site Tools


hv_bias

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
hv_bias [2013/12/14 15:26]
pereira [Object Scintillator]
hv_bias [2013/12/14 15:44]
pereira [General Information]
Line 3: Line 3:
  
 ===== General Information ===== ===== General Information =====
-The TPPACs, the Ion Chamber, and the CRDCs have ISEG power supplies run through a single VME-based bias control. The computer interface for this bias controlthe S800 Detector HV Controlis typically run on the devop1 computer in Data-U6 and is started by clicking on S800 HV under the Operations option on the taskbar. The Object scintillator and the FP Scintillator are each controlled separately as described below under the sections for each detector.+The [[Detectors#Tracking Parallel Plate Avalanche Counters (TPPAC)|TPPACs]], the [[Detectors#Ionization Chamber|Ion Chamber]], and the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDCs]] have ISEG power supplies run through a single VME-based bias control. The computer interface for this bias control -- the S800 Detector HV Control -- is typically run on the **devop1** computer in data-U6 and is started by clicking on **S800 HV** under the Operations option on the taskbar. The [[Detectors#Plastic scintillators|Object scintillator]] and the [[Detectors#Plastic scintillators|FP Scintillator]] are each controlled separately as described below under the sections for each detector.
  
 ===== Object Scintillator ===== ===== Object Scintillator =====
-The bias for the object scintillator is controlled via the Canberra HV supply located in the left rack in data-U6 in the NIM bin just underneath the NMR scopes.+The bias for the object scintillator is controlled via the H.V. power supply {{:wiki:Manual_Canberra_HV_3002D.pdf|Canberra model 3002 D}} located in the crate to the right of the data-U6. The voltage will be adjusted at the beginning of the experiment. This scintillator has to be turned off or put on "standby" when entering the vault due to its sensitivity to light.
  
 ===== FP Scintillators ===== ===== FP Scintillators =====
hv_bias.txt ยท Last modified: 2023/10/17 09:40 by noji