User Tools

Site Tools


hv_bias

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
hv_bias [2013/12/14 16:03]
pereira [TPPACs]
hv_bias [2014/11/19 11:43]
pereira [General Information]
Line 3: Line 3:
  
 ===== General Information ===== ===== General Information =====
-The [[Detectors#Tracking Parallel Plate Avalanche Counters (TPPAC)|TPPACs]], the [[Detectors#Ionization Chamber|Ion Chamber]], and the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDCs]] have ISEG power supplies run through a single VME-based bias control. The computer interface for this bias control -- the S800 Detector HV Control -- is typically run on the **devop1** computer in data-U6 and is started by clicking on **S800 HV** under the Operations option on the taskbar. The [[Detectors#Plastic scintillators|Object scintillator]] and the [[Detectors#Plastic scintillators|FP Scintillator]] are each controlled separately as described below under the sections for each detector.+The high-voltage of the [[Detectors#Tracking Parallel Plate Avalanche Counters (TPPAC)|TPPACs]], [[Detectors#Ionization Chamber|Ion Chamber]], the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDCs]], [[Detectors#Plastic scintillators|FP Scintillator]], and [[Detectors#Hodoscope|Hodoscope]] are remotely controlled via GUI control panel (see figure below). The GUI can be opened from the desktop of the u6pc5 control computer. This application allows also to set a maximum limit in the detector current. The voltages of these detectors depend on the Z of the fragments to be measured and their energy. The figure below shows the HV GUI during experiment e10002, which used Si-26 and Al-25 fragments at around 115 MeV/u. These voltages can be used as a reference before starting an experiment. However, the final values will have to be modified during the beam tuning in order to optimize the performance of the detectors. It is convenient to verify the reference values with D. Bazin. 
 + 
 +{{:wiki:hv-gui.png?700|GUI control panel of the S800 detectors HV}} 
 + 
 + 
 + 
 +detectors 
 + 
 +[[Detectors#Tracking Parallel Plate Avalanche Counters (TPPAC)|TPPACs]], the [[Detectors#Ionization Chamber|Ion Chamber]], and the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDCs]] have ISEG power supplies run through a single VME-based bias control. The computer interface for this bias control -- the S800 Detector HV Control -- is typically run on the **devop1** computer in data-U6 and is started by clicking on **S800 HV** under the Operations option on the taskbar. The [[Detectors#Plastic scintillators|Object scintillator]] and the [[Detectors#Plastic scintillators|FP Scintillator]] are each controlled separately as described below under the sections for each detector. 
 + 
  
 ===== Object Scintillator ===== ===== Object Scintillator =====
hv_bias.txt · Last modified: 2023/10/17 09:40 by noji