This shows you the differences between two versions of the page.
Next revision | Previous revision Next revision Both sides next revision | ||
preparation_for_tuning_the_s800 [2013/12/13 19:29] pereira created |
preparation_for_tuning_the_s800 [2013/12/13 20:28] pereira |
||
---|---|---|---|
Line 1: | Line 1: | ||
====== Preparation for tuning ====== | ====== Preparation for tuning ====== | ||
- | * [[Software]] | + | * [[Software|Software overview]] |
- | * [[Electronics]] | + | * [[Electronics |
* [[Gas handling system]] | * [[Gas handling system]] | ||
* [[HV bias]] | * [[HV bias]] | ||
Line 7: | Line 7: | ||
* [[Turning magnets on/off]] | * [[Turning magnets on/off]] | ||
* [[Magnetic-rigidity setting]] | * [[Magnetic-rigidity setting]] | ||
- | |||
- | ELECTRONICS, | ||
- | data-U6 (south end) | ||
- | Electronic location: two racks that contain all the electronics and patch panels. | ||
- | Oscilloscope TEKSCOPE11 | ||
- | Use: S800 detector/ | ||
- | Location: | ||
- | NMR Oscilloscopes | ||
- | Use: NMR resonances display | ||
- | Location: upper two shelves on right electronics rack | ||
- | NIM bin | ||
- | Location: below NMR scopes in right electronics racks | ||
- | Use: Canberra HV supply for Object scintillator | ||
- | Upper patch panels (top of left rack) | ||
- | Cables 1-10: to object | ||
- | Cables 11-20: | ||
- | Cables 21-25: | ||
- | Cable 26 is missing | ||
- | Cable 27-50 should go to pivot point (mostly not connect in vault) | ||
- | Middle patch panel (top of left rack) | ||
- | Cables 51-70: | ||
- | SHV cables 1-2: to object | ||
- | SHV cables 6-10: should go to intermediate image box (apparently not connected in vault) | ||
- | SHV cables 11-20: | ||
- | |||
- | S800 FP (top level of S3 vault) | ||
- | Electronics location: | ||
- | Patch panels: | ||
- | SHV Cables 21-30: | ||
- | Cables 51-70: | ||
- | Cables 91-110: | ||
- | |||
- | Pivot point (bottom level of S3 vault) | ||
- | Electronics location: | ||
- | Patch panels | ||
- | Cables 75-110: | ||
- | Cables 70-80: | ||
- | Cables 81-90: | ||
- | Cables 91-110: | ||
- | |||
- | Intermediate Image (accessed via middle level of S3 vault) | ||
- | Electronics location: | ||
- | Patch panels (in electronics rack on top level of S3 vault) | ||
- | Cables 21-25: | ||
- | Cables 81-90: | ||
- | |||
- | Object position (access via middle level of S3 vault) | ||
- | Electronics location: | ||
- | Patch panels (mounted on object box support under object box) | ||
- | Cables 11-20: | ||
- | Cables 71-80: | ||
- | SHV cables 1-2: to Data-U6 | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||