Line 4: Line 4:
     * [[#Run Control Window]]     * [[#Run Control Window]]
     * [[#EventBuilder Window]]     * [[#EventBuilder Window]]
 +    * [[#Mesytec CFD GUI]]
     * [[#Delay Window]]     * [[#Delay Window]]
     * [[#Trigger GUI]]     * [[#Trigger GUI]]
Line 48: Line 49:
  
   * To load the default CFD configuration go to **Load Setting**, select file **MCFD16.tcl** in directory **/user/operations/daq/usb/Config**, and click **Load**   * To load the default CFD configuration go to **Load Setting**, select file **MCFD16.tcl** in directory **/user/operations/daq/usb/Config**, and click **Load**
-  +   * Alternatively, it is possible to lead the configuration directly from the module by clicking **Update from Device**
-  * Alternatively, it is possible to lead the configuration directly from the module by clicking **Update from Device** +
   * By default, the CFD parameters can be adjusted individually for each of the 16 channels. It is also possible use the module in a "common" mode to set the same CFD parameters to all channels. Just check **common**   * By default, the CFD parameters can be adjusted individually for each of the 16 channels. It is also possible use the module in a "common" mode to set the same CFD parameters to all channels. Just check **common**
- +  * After modifying any of the CFD parameters, click **Commit to Device**
-  * After modifying any of the CFD parameters, click **Commit to Device**  +
- +
-  * After adjusting the thresholds, the new configuration must be saved in file **MCFD16.tcl** in directory **/user/operations/daq/usb/Config** +
   * The MCFD module includes the possibility to send a periodic pulsing signal to all the channels. Two frequencies can be selected: 1.22 KHz, and 2.5 MHz    * The MCFD module includes the possibility to send a periodic pulsing signal to all the channels. Two frequencies can be selected: 1.22 KHz, and 2.5 MHz 
  
Line 62: Line 57:
  
 ==== Delay Window ==== ==== Delay Window ====
-{{:wiki:482px-Runcontrol.png|Run Control Window}}+{{:wiki:delay-window.png|Delay GUI}}
  
  