Line 90: | Line 90: | ||
There are several common reasons why the S800 DAQ may fails to start. The list below describes what to do to fix these problems. | There are several common reasons why the S800 DAQ may fails to start. The list below describes what to do to fix these problems. | ||
+ | * [[No data sources defined]] | ||
+ | ==== No data sources defined ==== | ||
+ | When clicking '' | ||
+ | - Go to **/ | ||
+ | - Copy the file **.settings.tcl** from that directory to the current stagearea. **NOTE**: we are assuming that the stagearea is pointing to the new experiment directory **/ | ||
+ | - If you cannot find that file, there is an old version that can be copied from the directory **/ | ||
+ | - You should now be able to run ReadoutGUI without problem | ||
==== CCUSB and/or VMUSB claimed by existing programs ==== | ==== CCUSB and/or VMUSB claimed by existing programs ==== | ||
One of the most common reasons why the S800 DAQ fails to start is because the CCUSB and/or VMUSB are claimed by existing programs. This is shown by the error messages displayed by the system. If you find yourself in this situation try the following: | One of the most common reasons why the S800 DAQ fails to start is because the CCUSB and/or VMUSB are claimed by existing programs. This is shown by the error messages displayed by the system. If you find yourself in this situation try the following: |