Line 8: Line 8:
     * [[#Scaler Display]]     * [[#Scaler Display]]
   * [[#Troubleshooting]]   * [[#Troubleshooting]]
-  * [[#How to run combined S800 + GRETINA]]+
  
  
Line 44: Line 44:
  
   * To load the default CFD configuration go to **Load Setting**, select file **MCFD16.tcl** in directory **/user/operations/daq/usb/Config**, and click **Load**   * To load the default CFD configuration go to **Load Setting**, select file **MCFD16.tcl** in directory **/user/operations/daq/usb/Config**, and click **Load**
-   * Alternatively, it is possible to load the configuration directly from the module by clicking **Update from Device**. However, the names of the channels will not be displayed+   * Alternatively, it is possible to load the configuration directly from the module by clicking **Update from Device**.  
-  * By default, the CFD parameters can be adjusted individually for each of the 16 channels. It is also possible use the module in a "common" mode to set the same CFD parameters to all channels. Just check **common**+   * By default, the CFD parameters can be adjusted individually for each of the 16 channels. It is also possible use the module in a "common" mode to set the same CFD parameters to all channels. Just check **common**
   * After modifying any of the CFD parameters, click **Commit to Device**   * After modifying any of the CFD parameters, click **Commit to Device**
   * The MCFD module includes the possibility to send a periodic pulsing signal to all the channels. Two frequencies can be selected: 1.22 KHz, and 2.5 MHz    * The MCFD module includes the possibility to send a periodic pulsing signal to all the channels. Two frequencies can be selected: 1.22 KHz, and 2.5 MHz 
Line 129: Line 129:
 In the rare case that the RunControl GUI gets "frozen", it is possible to reboot the whole system manually. This operation requires to turn off the VME and CAMAC crates, and the spdaq computer, all them located in the rack seating near the FP box in the S3 vault. Then, the system must be turned back on in the following order. First, CAMAC crate, second VME crate, and third spdaq. In the rare case that the RunControl GUI gets "frozen", it is possible to reboot the whole system manually. This operation requires to turn off the VME and CAMAC crates, and the spdaq computer, all them located in the rack seating near the FP box in the S3 vault. Then, the system must be turned back on in the following order. First, CAMAC crate, second VME crate, and third spdaq.
  
- 
- 
-===== How to run combined S800 + GRETINA ===== 
-OBSOLETE. Documentation is currently under development. 
- 
- 
-In order to run the combined S800 + Gretina daq, the following steps need to be taken: 
- 
-1. On spdaq48 in /user/s800/operations/daq/usb/TclXXUSB do: 
- 
-**wish ./RunControl.tcl** 
- 
-or, on devop2 (the S800 MAC machine) 
- 
-click on the operations folder on the lower icon bar and select runcontrol.command 
- 
-2. On a dataU machine logged in as the experimental account (e11007 for the June 2012 testing period) do 
- 
-**godaq** 
- 
-3. On spdaq44 do:  
- 
-**/usr/opt/daq/10.1/bin/ringbuffer status**. The output should look similar to: 
- 
-<code> 
- +----------------+------------+-------+-------------+--------+---------+---------+------+-------------+ 
- |Name            |data-size(k)|free(k)|max_consumers|producer|maxget(k)|minget(k)|client|clientdata(k)| 
- +----------------+------------+-------+-------------+--------+---------+---------+------+-------------+ 
- |0400x           |8195        |8195   |100          |-1      |0        |0        |-     |-            | 
- |s800            |8195        |8195   |100          |7485    |0        |0        |-     |-            | 
- |-               |-           |-      |-            |-       |-        |-        |9143  |0            | 
- |segatest        |8195        |8195   |100          |-1      |0        |0        |-     |-            | 
- |spdaq48.0400x   |8195        |8195   |100          |17205   |0        |0        |-     |-            | 
- |spdaq48.segatest|8195        |8195   |100          |-1      |0        |0        |-     |-            | 
- +----------------+------------+-------+-------------+--------+---------+---------+------+-------------+ 
-</code> 
- 
-Upon start of run there will be another client of the s800 ring, which is the pushToGEB process. This should die on end run. 
- 
- 
-The S800 daq will now be in slave mode, and run control is done from the NSCL daq window. 
  
  
  
s800_daq_tools.txt · Last modified: 2023/10/19 17:25 by swartzj