This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
s800_daq_tools [2017/04/08 13:30] pereira [Delay Window] |
s800_daq_tools [2017/06/16 19:02] pereira [Running in Slave mode with multilogger] |
||
---|---|---|---|
Line 7: | Line 7: | ||
* [[#Trigger GUI]] | * [[#Trigger GUI]] | ||
* [[#Scaler Display]] | * [[#Scaler Display]] | ||
+ | * [[#Running in Slave mode with multilogger]] | ||
* [[# | * [[# | ||
Line 83: | Line 84: | ||
{{: | {{: | ||
- | The Trigger GUI appears when the "Init" button is pressed on the CAMAC crate controller tab as part of the initial setup of the [[s800 daq tools#run control window|S800 USB daq]]. The Trigger GUI is a visual display of the various Gate and Delay Generators and logic elements that make up the configurable trigger of the S800. The logic of the trigger decision is readily discerned from a visual inspection of this GUI. Setting the trigger configuration is also done using this GUI by right clicking | + | The Trigger GUI appears when the "Launch ULM GUI" button is pressed on [[#Readout GUI]]. The Trigger GUI is a visual display of the various Gate and Delay Generators and logic elements that make up the configurable trigger of the S800. The logic of the trigger decision is readily discerned from a visual inspection of this GUI. Setting the trigger configuration is also done using this GUI |
+ | |||
+ | The different signal going through the trigger scheme can be inspected in th Data-U6 oscilloscope. Simply | ||
Line 95: | Line 98: | ||
{{: | {{: | ||
+ | |||
+ | |||
+ | ==== Running in Slave mode with multilogger ==== | ||
+ | The S800 DAQ can be run in Standalone mode (as described above), or in Slave mode. The later means that the S800 DAQ is controlled by an external DAQ (e.g. GRETINA). In this mode, the S800 ULM receives external clock and external synchronization | ||
+ | |||
+ | |||
+ | By default, when running in Slave mode, data are recorded in the stagearea of the Master DAQ (experiment account). It is however possible to record simultaneously data from the S800 into the S800 stagearea, using the '' | ||
+ | |||
+ | Before running an experiment with a Master system (e.g. GRETINA), it is recommendable to run the S800 DAQ in Slave mode with the s800filter multilogger enabled. This can be done following the steps: | ||
+ | |||
+ | * Click to the tab '' | ||
+ | * Select the option " | ||
+ | * Click again on the tab '' | ||
+ | * Check out the ring-buffer " | ||
+ | * After this, S800 data from every run recorded by the experimenters, | ||
+ | |||
+ | |||
+ | |||
+ | |||