s800_daq_tools [2017/06/16 19:06]
pereira [Running in Slave mode with multilogger]
s800_daq_tools [2017/07/17 17:39]
pereira [Troubleshooting]
Line 106: Line 106:
 By default, when running in Slave mode, data are recorded in the stagearea of the Master DAQ (experiment account). It is however possible to record simultaneously data from the S800 into the S800 stagearea, using the ''multilogger'' option (see ReadoutGUI figure above). The S800 ReadougGUI offers the possibility to record data from four different S800 ring-buffers: rawccusb, rawvmusb, s800built, and s800filter. The later is the most important since data from this ring buffer can be immediately processed by the S800 SpecTcl.  By default, when running in Slave mode, data are recorded in the stagearea of the Master DAQ (experiment account). It is however possible to record simultaneously data from the S800 into the S800 stagearea, using the ''multilogger'' option (see ReadoutGUI figure above). The S800 ReadougGUI offers the possibility to record data from four different S800 ring-buffers: rawccusb, rawvmusb, s800built, and s800filter. The later is the most important since data from this ring buffer can be immediately processed by the S800 SpecTcl. 
  
-Before running an experiment with a Master system (e.g. GRETINA), it is recommendable to run the S800 DAQ in Slave mode with the s800filter multilogger enabled. This can be done following the steps:+When running XDT for an experiment with a Master DAQ (e.g. GRETINA), it is recommendable to run the S800 DAQ in Slave mode with the s800filter multilogger enabled. This can be done following the steps:
  
   * Click to the tab ''multilogger'' in the **ReadoutGUI**   * Click to the tab ''multilogger'' in the **ReadoutGUI**
Line 117: Line 117:
  
   * After this, S800 data from every run recorded by the experimenters, will also be recorded in the S800 stagearea.   * After this, S800 data from every run recorded by the experimenters, will also be recorded in the S800 stagearea.
 +
 +  * After finishing XDT, it is better to disable the s800filter ring-buffer in the multilogger menu so the S800 stagearea doesn't record all data from the experiment.
  
  
Line 122: Line 124:
  
 ===== Troubleshooting ===== ===== Troubleshooting =====
-There are several common reasons why the S800 DAQ may fails to start. The list below describes what to do to fix these problems. +There are several common reasons why the S800 DAQ may fail. The list below describes what to do to fix some of these problems. 
-  * [[#Old processes still running]]   +  * [[#Old processes still running|Error message: "Socket ID already in use"]]   
   * [[#No data sources defined]]   * [[#No data sources defined]]
   * [[#CCUSB and/or VMUSB claimed by existing programs]]   * [[#CCUSB and/or VMUSB claimed by existing programs]]
s800_daq_tools.txt · Last modified: 2023/10/19 17:25 by swartzj