-After initializing the contollers, the ReadoutGUI window will show the ''Begin'' button active. In addition, three additional buttons should appear at the end of the window. They can be used to start the GUI associated with the [[#Mesytec CFD GUI|MCFD]], [[#Delay Window|Delay XLM]], and [[#Trigger GUI|Trigger ULM]] modules. Make sure that the system is completely initializing before opening those GUIs.+After initializing the controllers, the ReadoutGUI window will show the ''Begin'' button active. In addition, three additional buttons should appear at the end of the window. They can be used to start the GUI associated with the [[#Mesytec CFD GUI|MCFD]], [[#Delay Window|Delay XLM]], and [[#Trigger GUI|Trigger ULM]] modules. Make sure that the system is completely initializing before opening those GUIs.
  
 Before beginning a run, you have to make sure that the ULM trigger module is properly configured. This can be done by clicking the button [[#Trigger GUI|Launch ULM GUI]] in the ReadoutGUI window. Before beginning a run, you have to make sure that the ULM trigger module is properly configured. This can be done by clicking the button [[#Trigger GUI|Launch ULM GUI]] in the ReadoutGUI window.
Line 168: Line 168:
 ==== For hodoscope runs, cannot read signal from hodoscope ==== ==== For hodoscope runs, cannot read signal from hodoscope ====
 If you see this kind error message when starting the DAQ with the hodoscope in the trigger (Ext. 1 in ULM gui), check the voltages on the crate which holds the hodoscope shaper modules. If they are not at the correct values, follow this procedure:  If you see this kind error message when starting the DAQ with the hodoscope in the trigger (Ext. 1 in ULM gui), check the voltages on the crate which holds the hodoscope shaper modules. If they are not at the correct values, follow this procedure: 
-  - Ordered List ItemTurn crate off+  - Turn crate off
   - Unplug both shapers (for both hodoscopes). Just pull them but don’t fully remove the cards.    - Unplug both shapers (for both hodoscopes). Just pull them but don’t fully remove the cards. 
   - With shapers unplugged, turn crate on and check voltages   - With shapers unplugged, turn crate on and check voltages