This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
s800_spectcl [2013/12/12 13:25] pereira [Sample spectra] |
s800_spectcl [2014/12/03 18:17] pereira [S800 SpecTcl] |
||
---|---|---|---|
Line 3: | Line 3: | ||
- | The SpecTcl Control has been adapted for special functions required for the analysis of S800 data. Fig xxx shows the GUI control of the S800 analysis. | + | The SpecTcl Control has been adapted for special functions required for the analysis of S800 data. SpecTcl can be open by from computer [[software|u6pc5]] by clicking in the corresponding icon located in its desktop. The figure below shows the GUI control of the S800 analysis. |
{{: | {{: | ||
Line 9: | Line 9: | ||
- | The inverse map which enables the trajectory reconstruction of the particles within the spectrograph beam line can be loaded. Snapshots of CRDC and TPPAC events sampled in the pads and strips can be viewed. If this option is " | + | The inverse map which enables the trajectory reconstruction of the particles within the spectrograph beam line can be loaded. Snapshots of [[Detectors# |
Line 66: | Line 66: | ||
- | **Energy loss in the ion chamber vs. time of flight measured between the object scintillator and the E1 scintillator (trigger) at the end of the focal plane. ** | + | ==== Energy loss in the ion chamber vs. time of flight measured between the object scintillator and the E1 scintillator (trigger) at the end of the focal plane ==== |
{{: | {{: | ||
Line 77: | Line 77: | ||
// | // | ||
- | **(In)elastic scattering of the incoming " | + | ====(In)elastic scattering of the incoming " |
{{: | {{: | ||
- | **Upper left**: Three 124Sn charge states in the CRDC2 x-y spectrum | ||
- | **Upper right**: Amplitude of the CRDC2 anode signal vs. drift time (this is a diagnostics spectrum showing that the response of the CRDC is not correlated with the y position). | ||
- | **Lower left**: Raw drift time measured in CRDC2 | ||
- | **Lower right**: Charge distribution induced in the pads by the three 124Sn charge states hitting CRDC2. | + | ==== Sn-124 primary beam passing a thick Al viewer at the target position (focused optics) ==== |
+ | {{: | ||
+ | **Upper left**: Three < | ||
+ | **Upper right**: Amplitude of the CRDC2 anode signal vs. drift time (this is a diagnostics spectrum showing that the response of the CRDC is not correlated with the y position). | ||
+ | **Lower left**: Raw drift time measured in CRDC2 | ||
- | + | **Lower right**: Charge distribution induced in the pads by the three < | |
- | + | ||
- | + | ||
- | + | ||
- | **< | + | |
- | + | ||
- | {{: | + | |