User Tools

Site Tools


start

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
start [2013/09/30 21:05]
pereira
start [2013/09/30 21:09]
pereira
Line 7: Line 7:
  
 {{:wiki:s800_layout.png|}} {{:wiki:s800_layout.png|}}
 +
  
 ==== Analysis Line ==== ==== Analysis Line ====
Line 13: Line 14:
  
 ==== Spectrograph ==== ==== Spectrograph ====
-The spectrograph consist of two quadrupoles, a sextupole and two big dipoles assembled in a QQ-S-DD configuration (segment 8) that spans vertically from the target station to the focal plane, with a total length of 18 m. The figures of merit of the spectrograph are summarized in Table 1. Achieving the nominal angle and momentum resolution require the control of different conditions such as object size (less than 0.5 mm), target thickness, uncertainty of the incident angle on the target, intensity, and whether or not the incoming beam needs to be tracked. +The spectrograph consist of two quadrupoles, a sextupole and two big dipoles assembled in a QQ-S-DD configuration (segment 8) that spans vertically from the target station to the focal plane, with a total length of 18 m. The figures of merit of the spectrograph are summarized in [[start|Table 1]]. Achieving the nominal angle and momentum resolution require the control of different conditions such as object size (less than 0.5 mm), target thickness, uncertainty of the incident angle on the target, intensity, and whether or not the incoming beam needs to be tracked. 
  
  
start.txt ยท Last modified: 2024/01/02 12:45 by pereira