Line 9: Line 9:
 {{:wiki:s800_layout.png|}} {{:wiki:s800_layout.png|}}
  
 +=== Analysis Line ===
  
-==== Analysis Line ==== 
 The analysis line extends from the object position to the target station, with a total length of 22 m. It includes four 22.5° dipoles, five quadrupole triplets, and two vertically steering magnets, assembled in two segments with configurations QQQ-H-DD-QQQ (segment 6) and QQQ-DD-H-QQQ-QQQ (segment 7) symmetrically oriented around an intermediate image plane. The maximum rigidity is 5 Tm, although it depends on the tune of the quadrupoles. The acceptances of the analysis line depends on the optical mode. The analysis line extends from the object position to the target station, with a total length of 22 m. It includes four 22.5° dipoles, five quadrupole triplets, and two vertically steering magnets, assembled in two segments with configurations QQQ-H-DD-QQQ (segment 6) and QQQ-DD-H-QQQ-QQQ (segment 7) symmetrically oriented around an intermediate image plane. The maximum rigidity is 5 Tm, although it depends on the tune of the quadrupoles. The acceptances of the analysis line depends on the optical mode.
  
  
-==== Spectrograph ====+=== Spectrograph ===
 The spectrograph consist of two quadrupoles, a sextupole and two big dipoles assembled in a QQ-S-DD configuration (segment 8) that spans vertically from the target station to the focal plane, with a total length of 18 m. The figures of merit of the spectrograph are summarized in Table 1. Achieving the nominal angle and momentum resolution require the control of different conditions such as object size (less than 0.5 mm), target thickness, uncertainty of the incident angle on the target, intensity, and whether or not the incoming beam needs to be tracked.  The spectrograph consist of two quadrupoles, a sextupole and two big dipoles assembled in a QQ-S-DD configuration (segment 8) that spans vertically from the target station to the focal plane, with a total length of 18 m. The figures of merit of the spectrograph are summarized in Table 1. Achieving the nominal angle and momentum resolution require the control of different conditions such as object size (less than 0.5 mm), target thickness, uncertainty of the incident angle on the target, intensity, and whether or not the incoming beam needs to be tracked. 
  
start.txt · Last modified: 2024/01/02 12:45 by pereira