User Tools

Site Tools


start

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
start [2013/09/30 21:42]
pereira
start [2013/10/16 10:47]
pereira
Line 4: Line 4:
  
 ==== General ==== ==== General ====
-The S800 [1] is a superconducting spectrograph used for reaction studies with high-energy radioactive beams produced at the NSCL Coupled-Cyclotron Facility (CCF) and the A1900 Separator [2]. It was designed for high-precision measurements of scattering angles (ΔΘ=2 msr) and momentum (p/Δp=2×10<sup>4</sup>), and large momentum and solid-angle acceptances (ΔΩ=20 msr, Δp/p=6%). The S800 layout is shown in Fig. 1. It consists of two parts: the analysis line and the spectrograph. +The [[wiki:S800]] [1] is a superconducting spectrograph used for reaction studies with high-energy radioactive beams produced at the NSCL Coupled-Cyclotron Facility (CCF) and the A1900 Separator [2]. It was designed for high-precision measurements of scattering angles (ΔΘ=2 msr) and momentum (p/Δp=2×10<sup>4</sup>), and large momentum and solid-angle acceptances (ΔΩ=20 msr, Δp/p=6%). The S800 layout is shown in Fig. 1. It consists of two parts: the analysis line and the spectrograph.  
 + 
 + 
 +[[wiki:pirolilla]]
  
  
Line 48: Line 51:
 Some detection systems do not require a scattering chamber. In this case, the chamber will be removed and the target is slid into a pipe surrounded by the detector array. SeGA, CAESAR, GRETINA, PLUNGER, LENDA have standard frames and setups to be used with the S800. Other detector arrays would require the design and fabrication of new hardware. In this configuration a target change presently requires venting the target section and dismounting part of the hardware to access the inside of the beam pipe. This operation typically takes about 30-45 minutes.  Some detection systems do not require a scattering chamber. In this case, the chamber will be removed and the target is slid into a pipe surrounded by the detector array. SeGA, CAESAR, GRETINA, PLUNGER, LENDA have standard frames and setups to be used with the S800. Other detector arrays would require the design and fabrication of new hardware. In this configuration a target change presently requires venting the target section and dismounting part of the hardware to access the inside of the beam pipe. This operation typically takes about 30-45 minutes. 
  The S800 focal plane box (see (picture) Fig. xxx) is equipped with various detectors including two position sensitive Cathode Readout Drift Chambers (CRDCs) for tracking the trajectories of the particles, a ion chamber for the measurement of energy loss, a timing scintillator  E1, and an Hodoscope for total kinetic energy measurements.  The S800 focal plane box (see (picture) Fig. xxx) is equipped with various detectors including two position sensitive Cathode Readout Drift Chambers (CRDCs) for tracking the trajectories of the particles, a ion chamber for the measurement of energy loss, a timing scintillator  E1, and an Hodoscope for total kinetic energy measurements.
 +
 +
 +{{:wiki:s800_layout.png|}}
 +
  
  
Line 63: Line 70:
 === Spectrograph Sextupole === === Spectrograph Sextupole ===
 The only high-order magnet included in the S800 is a sextupole coil  installed around the bore tube of Q2. The purpose of this element is to correct the broadening of the beam at the focal plane due to the dominant (x|2) aberration. This defines a narrower trajectory of the beam, allowing the use of a beam blocker at the focal plane to block the unreacted beam when its magnetic rigidity is close to the tuned setting.  The only high-order magnet included in the S800 is a sextupole coil  installed around the bore tube of Q2. The purpose of this element is to correct the broadening of the beam at the focal plane due to the dominant (x|2) aberration. This defines a narrower trajectory of the beam, allowing the use of a beam blocker at the focal plane to block the unreacted beam when its magnetic rigidity is close to the tuned setting. 
 +
 +
 +
 +
 +
 +
 +
  
  
start.txt · Last modified: 2024/01/02 12:45 by pereira