This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
trigger [2016/03/16 15:02] pereira [Configuration for S800 in tandem with other detectors] |
trigger [2023/10/24 16:47] swartzj [Trigger schematics] |
||
---|---|---|---|
Line 36: | Line 36: | ||
===== Trigger schematics ===== | ===== Trigger schematics ===== | ||
- | The trigger schematic is shown on the Graphical User Interface (GUI) displayed in the figure below. The GUI is automatically displayed when clicking in the Readout icon of the [[software|u6pc5]] desktop. | + | The trigger schematic is shown on the Graphical User Interface (GUI) displayed in the figure below. The GUI is automatically displayed when clicking in the Readout icon of the [[software|u4pc8]] desktop. |
{{: | {{: | ||
Line 56: | Line 56: | ||
==== Inspect channels ==== | ==== Inspect channels ==== | ||
- | A set of four inspect channels are patched out to the data-U6 panels. Each channel can be assigned to any connection drawn on the GUI, thereby providing a convenient way to diagnose and adjust the timings at each step of the trigger circuit. | + | A set of four inspect channels are patched out to the data-U4 panels. Each channel can be assigned to any connection drawn on the GUI by right clicking on the corresponding drawn " |
Line 85: | Line 85: | ||
^ A4 (in) | External 2 source ^ B4 (out) | QDC gate ^ C4 (in) | Busy 4 ^ D4 (out) | External 2 source | | ^ A4 (in) | External 2 source ^ B4 (out) | QDC gate ^ C4 (in) | Busy 4 ^ D4 (out) | External 2 source | | ||
^ A5 (in) | Clear busy ^ B5 (out) | TDC start ^ C5 (in) | Busy 5 ^ D5 (out) | S800 trigger | | ^ A5 (in) | Clear busy ^ B5 (out) | TDC start ^ C5 (in) | Busy 5 ^ D5 (out) | S800 trigger | | ||
- | ^ A6 (in) | Clear module | + | ^ A6 (in) | Clear module |
^ A7 (in) | Gretina sync ^ B7 (out) | ^ C7 (in) | Busy 7 ^ D7 (out) | External 1 trigger | | ^ A7 (in) | Gretina sync ^ B7 (out) | ^ C7 (in) | Busy 7 ^ D7 (out) | External 1 trigger | | ||
^ A8 (in) | Time stamp clock ^ B8 (out) | Live trigger | ^ A8 (in) | Time stamp clock ^ B8 (out) | Live trigger | ||
Line 121: | Line 121: | ||
====== Configuration for S800 in tandem with other detectors ====== | ====== Configuration for S800 in tandem with other detectors ====== | ||
- | In its standard configuration, | + | In its standard configuration, |
To incorporate an external detector in the S800 trigger logic, the same busy and end-of-event signals are required from its data acquisition system. This is to ensure that no live trigger signal is generated when any of the partners is busy or still processing an event. The 5 signals necessary between the S800 trigger and an external data acquisition system are the following: | To incorporate an external detector in the S800 trigger logic, the same busy and end-of-event signals are required from its data acquisition system. This is to ensure that no live trigger signal is generated when any of the partners is busy or still processing an event. The 5 signals necessary between the S800 trigger and an external data acquisition system are the following: | ||
Line 156: | Line 156: | ||
====== Begin sequence ====== | ====== Begin sequence ====== | ||
+ | OBSOLETE: THIS SECTION IS BEING UPDATED | ||
+ | |||
The internal " | The internal " | ||