trigger [2016/03/16 15:03] pereira [Configuration for S800 in tandem with other detectors] |
trigger [2016/03/17 09:59] pereira [Begin sequence] |
| |
====== Begin sequence ====== | ====== Begin sequence ====== |
| OBSOLETE: THIS SECTION IS BEING UPDATED |
| |
The internal "Go" state of the trigger module is controlled via CAMAC commands. When "Go" is false, the trigger and time stamp clock signals are vetoed and therefore absent. This way all time stamp counters can be safely zeroed during the beginning sequence of the data acquisition systems. The last command of the CAMAC beginning sequence sets the "Go" state to true, at which point both trigger and time stamp signals are released. This mechanism ensures that all time stamp counters are synchronized. | The internal "Go" state of the trigger module is controlled via CAMAC commands. When "Go" is false, the trigger and time stamp clock signals are vetoed and therefore absent. This way all time stamp counters can be safely zeroed during the beginning sequence of the data acquisition systems. The last command of the CAMAC beginning sequence sets the "Go" state to true, at which point both trigger and time stamp signals are released. This mechanism ensures that all time stamp counters are synchronized. |
| |