This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
tuning_the_s800_xdt [2015/10/21 13:36] pereira |
tuning_the_s800_xdt [2015/10/21 14:00] pereira |
||
---|---|---|---|
Line 13: | Line 13: | ||
=== Send beam to FP === | === Send beam to FP === | ||
* Ensure that the S800 spectrograph magnets are tuned to the right rigidity | * Ensure that the S800 spectrograph magnets are tuned to the right rigidity | ||
+ | |||
+ | * Verify that the beam blocker (labeled I255 Slits) in the S3 page of Barney is open: | ||
+ | * Expected " | ||
* Ensure that CRAD04 (typically connected to object scintillator) is enabled with a rate limit of **20 kHz** (CRAD04 looks at E1 up FP scintillator) | * Ensure that CRAD04 (typically connected to object scintillator) is enabled with a rate limit of **20 kHz** (CRAD04 looks at E1 up FP scintillator) | ||
Line 42: | Line 45: | ||
* Use **[[electronics overview|scope]]** to look at signal patched out to data U6 (channel #54 in data U6 patch panel) | * Use **[[electronics overview|scope]]** to look at signal patched out to data U6 (channel #54 in data U6 patch panel) | ||
* This signal is sent to the CANBERRA 454 Quad CFD in data U6 | * This signal is sent to the CANBERRA 454 Quad CFD in data U6 | ||
+ | * One of the output from this CFD is sent (via patch panel #62) to the TAC and scaler (channel OBJ.Scint) in S3. The other output goes through a passive delayed, and is sent (via patch panel #67) to the Phillips TDC | ||
* Check raising time and amplitude. Good signal: ~10 ns raising time; 400-500 mV amplitude | * Check raising time and amplitude. Good signal: ~10 ns raising time; 400-500 mV amplitude | ||
- | * Using the scope, check the CFD setting | + | * Using the scope, check the CFD setting: |
* Check CFD walk inspect signal in scope by triggering scope with CFD output | * Check CFD walk inspect signal in scope by triggering scope with CFD output | ||
* Ensure that CFD delay cable is ok: about 80% of raising time of the input signal | * Ensure that CFD delay cable is ok: about 80% of raising time of the input signal | ||
- | * Adjust CFD threshold looking at scalers. The ratio of OBJ to XFP scaler rates should reflect the transmission of the cocktail beam | + | * Adjust CFD threshold looking at scalers. The ratio of OBJ to XFP scaler rates (channels OBJ.Scint and XFP.Scint) |
- | + | ||
+ | * Adjust MCFD threshold: | ||
+ | * The OBJ signal feeding this module is not patched out to data U6 | ||
+ | * The OBJ signal from MCFD-16 module goes to the Mesytec MTDC32 module and scaler (channel OBJ.MCFD.Scint) | ||
+ | * Adjust CFD threshold looking at scalers. The ratio of OBJ to XFP scaler rates (channels OBJ.MCFD.Scint and XFP.MCFD.Scint) should reflect the transmission of the cocktail beam | ||
+ | |||
+ | |||
* Watch for no rate change on scaler display with a bias adjustment up or down of about 50-100 V | * Watch for no rate change on scaler display with a bias adjustment up or down of about 50-100 V | ||
Line 55: | Line 64: | ||
=== FP scintillator setup === | === FP scintillator setup === | ||
- | * Set trigger to “s800 trigger” | + | * Set trigger to “s800 trigger” |
- | * Ensure that the **[[s800 daq tools# | + | * Ensure that the **[[s800 daq tools# |
- | * Under trigger tab select **s800 trigger** (which is E1 up by definition) | + | * Under trigger tab select **s800 trigger** (which is E1 up by definition) |
* Deselect experiment trigger | * Deselect experiment trigger | ||
* SAVE TO FILE | * SAVE TO FILE | ||
- | * Stop and start **[[s800 daq tools#Run Control Window|RunControl]]** to assert new trigger condition | + | * End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new trigger condition |
* Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** | * Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** | ||
Line 90: | Line 99: | ||
{{: | {{: | ||
- | * Gains are controlled in **s800shpini.tcl** file in directory | + | * Gains are controlled in **s800shpini.tcl** file in directory |
* First shaper is for ion chamber | * First shaper is for ion chamber | ||
* Typically, only coarse gains are used | * Typically, only coarse gains are used | ||
- | * Stop and start **[[s800 daq tools#Run Control Window|RunControl]]** to assert new gain values | + | * End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new gain values |