This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
tuning_the_s800_xdt [2015/10/21 13:57] pereira |
tuning_the_s800_xdt [2015/10/21 14:02] pereira |
||
---|---|---|---|
Line 14: | Line 14: | ||
* Ensure that the S800 spectrograph magnets are tuned to the right rigidity | * Ensure that the S800 spectrograph magnets are tuned to the right rigidity | ||
- | * Verify that the beam blocker (labeled I255 Slits) in the S3 Barney | + | * Verify that the beam blocker (labeled I255 Slits) in the S3 page of Barney |
- | * Expected " | + | * Expected " |
* Ensure that CRAD04 (typically connected to object scintillator) is enabled with a rate limit of **20 kHz** (CRAD04 looks at E1 up FP scintillator) | * Ensure that CRAD04 (typically connected to object scintillator) is enabled with a rate limit of **20 kHz** (CRAD04 looks at E1 up FP scintillator) | ||
Line 111: | Line 111: | ||
* Patched to data-U6 on labeled connector | * Patched to data-U6 on labeled connector | ||
* **200 – 500 mV** signals are good | * **200 – 500 mV** signals are good | ||
+ | * CRDC1 anode is noisier than CRDC2 (digital noise) | ||
* Bias CRDC1 and CRDC2. Typical starting values: | * Bias CRDC1 and CRDC2. Typical starting values: | ||
* For He-3 @ ~130 MeV/u: CRDC1 (Anode=1120 V, Drift=1000 V); CRDC2 (Anode=1120 V; Drift=1000 V) | * For He-3 @ ~130 MeV/u: CRDC1 (Anode=1120 V, Drift=1000 V); CRDC2 (Anode=1120 V; Drift=1000 V) |