User Tools

Site Tools


tuning_the_s800_xdt

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
tuning_the_s800_xdt [2015/10/22 16:43]
pereira
tuning_the_s800_xdt [2015/10/22 16:48]
pereira
Line 162: Line 162:
  
   * There are three electronic "sources" with time information for ToF calculation: Tennelec TACs, Phillips TDC, and Mesytec MTDC.    * There are three electronic "sources" with time information for ToF calculation: Tennelec TACs, Phillips TDC, and Mesytec MTDC. 
-  * Although the ToF reference ("start") in these three sources is given by the FP scintillator E1 up, the electronic path from the detector to each module is different (see {{:wiki:s800electronicstschematics-to20150907.pdf|main electronics diagram}} for more details) +  * Although the ToF reference ("start") in all the ToF modules is given by the FP scintillator E1 up, the electronic path from the detector to each module is different (see {{:wiki:s800electronicstschematics-to20150907.pdf|main electronics diagram}} for more details)
-  * The OBJ, XFP, and E1 up signals in the MTDC come from the Mesytec MCFD +
   * Before going to the ToF modules, the OBJ and XFP signals are sent to a CANBERRA CFD 454 CFD in data U6 from the data-U6 patch panel (OBJ: patch panel #54, XFP: patch panel #1)   * Before going to the ToF modules, the OBJ and XFP signals are sent to a CANBERRA CFD 454 CFD in data U6 from the data-U6 patch panel (OBJ: patch panel #54, XFP: patch panel #1)
   * MTDC:   * MTDC:
-      * The OBJ signal into the MCFD comes directly from the detector via S3 patch panel #94 (going to the target area+      * Before getting into the MTDC, the OBJ, XFP, and E1 up signals in the MTDC go through a Mesytec MCFD        
 +      * The OBJ signal into the MCFD comes directly from the detector via S3 patch panel #94 (i.e., there is no signal to check in data U6)
       * The XFP signal into the MCFD module comes from data-U6 patch panel #70, connected to the CANBERRA 454 CFD XFP output        * The XFP signal into the MCFD module comes from data-U6 patch panel #70, connected to the CANBERRA 454 CFD XFP output 
       * SpecTcl calculates the ToF by substracting the MTDC time from XFP (MTDC channel 2) or OBJ (MTDC channel 3) to the MTDC time from E1 up (MTDC channel 15)       * SpecTcl calculates the ToF by substracting the MTDC time from XFP (MTDC channel 2) or OBJ (MTDC channel 3) to the MTDC time from E1 up (MTDC channel 15)