tuning_the_s800_xdt [2015/10/22 16:48] pereira |
tuning_the_s800_xdt [2015/10/22 16:52] pereira |
||
---|---|---|---|
Line 168: | Line 168: | ||
* The OBJ signal into the MCFD comes directly from the detector via S3 patch panel #94 (i.e., there is no signal to check in data U6) | * The OBJ signal into the MCFD comes directly from the detector via S3 patch panel #94 (i.e., there is no signal to check in data U6) | ||
* The XFP signal into the MCFD module comes from data-U6 patch panel #70, connected to the CANBERRA 454 CFD XFP output | * The XFP signal into the MCFD module comes from data-U6 patch panel #70, connected to the CANBERRA 454 CFD XFP output | ||
- | * SpecTcl calculates the ToF by substracting the MTDC time from XFP (MTDC channel | + | * SpecTcl calculates the OBJ-to-Focal-Plane and XFP-to-Focal-Plane ToFs by substracting the E1 up time (MTDC channel |
* The MTDC timing signals do not require external delay adjustments because the matching window is sufficiently wide | * The MTDC timing signals do not require external delay adjustments because the matching window is sufficiently wide | ||
* Tennelec TACs: | * Tennelec TACs: |