 ==== Timing setup ==== ==== Timing setup ====
 At present, there are three electronic "sources" with time information for ToF calculation: ORTEC TACs, Phillips TDC, and Mesytec MTDC. Some background information can be found [[Timing|here]]. At present, there are three electronic "sources" with time information for ToF calculation: ORTEC TACs, Phillips TDC, and Mesytec MTDC. Some background information can be found [[Timing|here]].
 +
 +
 +  * Select SpecTcl window S800_TOF.win 
 +      * Make sure that the time range of spectra is wide enough (e.g. between -3000 to 3000) 
 + 
 +{{:wiki:SpecTcl-e14019-run103.jpg?850|S800_ToF.win page}}
  
   * Although the ToF reference ("start") in all the ToF modules is given by the FP scintillator E1 up, the electronic path from the detector to each module is different (see {{:wiki:s800electronicstschematics-to20150907.pdf|main electronics diagram}} for more details)   * Although the ToF reference ("start") in all the ToF modules is given by the FP scintillator E1 up, the electronic path from the detector to each module is different (see {{:wiki:s800electronicstschematics-to20150907.pdf|main electronics diagram}} for more details)
tuning_the_s800_xdt.txt ยท Last modified: 2023/09/22 15:15 by swartzj