tuning_the_s800_xdt [2015/10/26 13:25]
pereira [Timing setup]
tuning_the_s800_xdt [2015/10/26 13:58]
pereira [Checking Particle ID and rate at S800 FP]
Line 182: Line 182:
  
 ==== Checking Particle ID and rate at S800 FP ==== ==== Checking Particle ID and rate at S800 FP ====
-  Establish PID + 
-      * Refer to information on setting from A1900 FP +  * Select SpecTcl window **S800_PID.win** in directory **/user/s800/operations/spectcl/Windows**  
-      * dE-TOF +      * The three columns correspond to the PID determined with the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right) 
-           dE signal from Ion Chamber +      * The first (top) row corresponds to the Phillips TDC 
-           TOF from XF or Object scintillator to S800 FP +      The second row corresponds to the MTDC with just the first hit included 
-           Not necessary to implement dEor TOF-based corrections +      The third row corresponds to the ORTEC TACs. Note that there is not **RF-FP TAC** 
-      Document rate of fragment of interest with run to disk +      You might need to adjust the limits of the spectra to get a good resolution 
-          * Measure beam current with appropriate Faraday cups + 
-          Timed run+{{:wiki:SpecTcl-e14019-PID-r103.jpg?850|S800_PID.win page}} 
 + 
 + 
 +  Establish PID and measure rate 
 +      * Determine the blob that corresponds to the unreacted beam (refer to information on setting from A1900 FP) 
 +      * Take gates around the fragment of interest 
 +      * Measure the beam intensity the appropriate faraday cup 
 +      * Take a run on disk  
 +      * Measure the beam intensity again and calculate the average value 
 +      * In **[[s800 SpecTcl|SpecTcl GUI]], click **Attach to File** and select data file **run-xxxx-xx.evt** in directory **/user/s800/stagearea/experiment/runxxxx**, where xxxx stands for the run number 
 +      * Check the run time and live time from the corresponding scaler file in directory **/user/s800/converged_daq/scalers** 
 +      * Calculate the rate and purity and compare with the value in the A1900 FP to determine the transmission 
 + 
 + 
  
  
tuning_the_s800_xdt.txt · Last modified: 2023/09/22 15:15 by swartzj