* Confirm correlations between dispersive angle at intermediate image and p in FP (e.g., crdc1x). This correlation will be somewhat washed out by straggling in the target; in principle, this should be checked without the target, but the benefit vs. cost in time to remove the target is not worth it. | * Confirm correlations between dispersive angle at intermediate image and p in FP (e.g., crdc1x). This correlation will be somewhat washed out by straggling in the target; in principle, this should be checked without the target, but the benefit vs. cost in time to remove the target is not worth it. | ||
- | |||
- | |||
- | ==== Setup beamline ==== | ||
- | |||
- | * Object and XF scintillators and intermediate image PPACs inserted if they will be used | ||
- | * If Object scintillator will not be used, there is no reason to look at beam on it unless to debug a problem with the transmission | ||
- | |||
- | * Set spectrograph Brho for unreacted fragment | ||
- | |||
- | |||
- | ==== Start scalers ==== | ||
- | |||
- | * Use s800 account | ||
- | |||
- | * Make sure experiment daq is: | ||
- | * Stopped | ||
- | * Gone | ||
- | * Open terminal window (from bottom of mac) | ||
- | * ssh to spdaq20 | ||
- | * ps auw | grep Readout | ||
- | * Does not get restarted | ||
- | |||
- | * Under operations folder on mac | ||
- | * scalers (gives error if no bridge) | ||
==== Setting Optimization ==== | ==== Setting Optimization ==== | ||
Line 276: | Line 252: | ||
* Document optimized transmission with another run to disk to measure rate of fragment of interest at S800 FP | * Document optimized transmission with another run to disk to measure rate of fragment of interest at S800 FP | ||
- | |||
- | |||
- | === Matched optics === | ||
- | |||
- | * Typically much more time is invested for optimizing optics for matched optics than for focused optics | ||
- | |||
- | * One input is optimizing for transmission | ||
- | |||
- | * For tritons a scintillator is required at the pivot position since fragments at 5 Tm will not reach S800 FP | ||
- | |||
- | * The last two analysis line triplets are used to tweak for the desired optical properties | ||
- | |||
- | * Document optimized transmission with another run to disk to measure rate of fragment of interest at S800 FP | ||