User Tools

Site Tools


tuning_the_s800_xdt

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
tuning_the_s800_xdt [2015/10/26 14:11]
pereira [Analysis line classic PPAC setup (Focus optics only)]
tuning_the_s800_xdt [2015/10/26 14:14]
pereira [Setting Optimization]
Line 238: Line 238:
  
 ==== Setting Optimization ==== ==== Setting Optimization ====
- 
-=== Focused optics === 
  
   * Expectations for A1900 FP to S800 FP transmission   * Expectations for A1900 FP to S800 FP transmission
Line 249: Line 247:
       * Want to balance losses between S800 analysis line and Transfer Hall (the S800 analysis line is typically slightly worse)       * Want to balance losses between S800 analysis line and Transfer Hall (the S800 analysis line is typically slightly worse)
       * Best diagnostic is scalers from S800 FP, object scintillator and XF scintillator       * Best diagnostic is scalers from S800 FP, object scintillator and XF scintillator
-      * Tweak y-quads (while watching scalers) in front of dipole gaps (this works both for Transfer Hall and analysis line); choose elements that have biggest effect with smallest ratio change+      * Using knob box and Tweak y-quads (while watching scalers) in front of dipole gaps (this works both for Transfer Hall and analysis line); choose elements that have biggest effect with smallest ratio change
  
   * Document optimized transmission with another run to disk to measure rate of fragment of interest at S800 FP   * Document optimized transmission with another run to disk to measure rate of fragment of interest at S800 FP
tuning_the_s800_xdt.txt ยท Last modified: 2023/09/22 15:15 by swartzj