tuning_the_s800_xdt [2015/10/26 14:11] pereira [Analysis line classic PPAC setup (Focus optics only)] |
tuning_the_s800_xdt [2015/10/26 15:08] pereira [Coincidences] |
||
---|---|---|---|
Line 238: | Line 238: | ||
==== Setting Optimization ==== | ==== Setting Optimization ==== | ||
- | |||
- | === Focused optics === | ||
* Expectations for A1900 FP to S800 FP transmission | * Expectations for A1900 FP to S800 FP transmission | ||
Line 249: | Line 247: | ||
* Want to balance losses between S800 analysis line and Transfer Hall (the S800 analysis line is typically slightly worse) | * Want to balance losses between S800 analysis line and Transfer Hall (the S800 analysis line is typically slightly worse) | ||
* Best diagnostic is scalers from S800 FP, object scintillator and XF scintillator | * Best diagnostic is scalers from S800 FP, object scintillator and XF scintillator | ||
- | * Tweak y-quads (while watching scalers) in front of dipole gaps (this works both for Transfer Hall and analysis line); choose elements that have biggest effect with smallest ratio change | + | * Using the knob box and the NCS application **QtKM** (file **BLSetup_A1900.gkm**), |
* Document optimized transmission with another run to disk to measure rate of fragment of interest at S800 FP | * Document optimized transmission with another run to disk to measure rate of fragment of interest at S800 FP | ||
Line 260: | Line 258: | ||
- | ====== Dispersion Matching | + | ====== Dispersion Matching |
In the dispersion-matching optics, the S800 focal point is achromatic, i.e. the position of the beam in the dispersive direction does not depend on the momentum. As a consequence, | In the dispersion-matching optics, the S800 focal point is achromatic, i.e. the position of the beam in the dispersive direction does not depend on the momentum. As a consequence, | ||
Line 335: | Line 333: | ||
* Probably smaller typical S800 delay needed for HiRA | * Probably smaller typical S800 delay needed for HiRA | ||
* An example of experiments where auxiliary detectors are not used and, thus, setting up coincidence timing is not an issue are the experiments with tritons run by the charge exchange group | * An example of experiments where auxiliary detectors are not used and, thus, setting up coincidence timing is not an issue are the experiments with tritons run by the charge exchange group | ||
- | * It is not clear whether coincidence setup gets logged as “XDT” or “EXR” | + | |
* Choice of setting to be used for coincidence timing setup | * Choice of setting to be used for coincidence timing setup | ||
* The reaction of interest for the experiment can be used to setup coincidences only if the rate of coincidences is high enough | * The reaction of interest for the experiment can be used to setup coincidences only if the rate of coincidences is high enough |