tuning_the_s800_xdt [2015/10/26 14:14]
pereira [Setting Optimization]
tuning_the_s800_xdt [2015/10/26 14:18]
pereira [Setting Optimization]
Line 247: Line 247:
       * Want to balance losses between S800 analysis line and Transfer Hall (the S800 analysis line is typically slightly worse)       * Want to balance losses between S800 analysis line and Transfer Hall (the S800 analysis line is typically slightly worse)
       * Best diagnostic is scalers from S800 FP, object scintillator and XF scintillator       * Best diagnostic is scalers from S800 FP, object scintillator and XF scintillator
-      * Using knob box and Tweak y-quads (while watching scalers) in front of dipole gaps (this works both for Transfer Hall and analysis line); choose elements that have biggest effect with smallest ratio change+      * Using the knob box and the NCS application **QtKM** (file **BLSetup_A1900.gkm**), tweak y-quads (while watching scalers) in front of dipole gaps (this works both for Transfer Hall and analysis line); choose elements that have biggest effect with smallest ratio change
  
   * Document optimized transmission with another run to disk to measure rate of fragment of interest at S800 FP   * Document optimized transmission with another run to disk to measure rate of fragment of interest at S800 FP