tuning_the_s800_xdt [2015/10/26 14:19] pereira [Dispersion Matching tuning] |
tuning_the_s800_xdt [2015/10/27 07:28] pereira [Object scintillator setup] |
||
---|---|---|---|
Line 55: | Line 55: | ||
* Adjust MCFD threshold: | * Adjust MCFD threshold: | ||
- | * Open configuration file **MCFD16.tcl** in **/user/s800/ | + | * Open the [[s800 daq tools# |
* The OBJ signal feeding this module is not patched out to data U6 | * The OBJ signal feeding this module is not patched out to data U6 | ||
- | * The OBJ signal from MCFD-16 module goes to the Mesytec | + | * The OBJ signal from MCFD module goes to the Mesytec |
* Make sure that the threshold of the XFP MCFD channel is reasonable. Rates in scaler channels XFP.Scint and XFP.MCFD.Scint should be comparable | * Make sure that the threshold of the XFP MCFD channel is reasonable. Rates in scaler channels XFP.Scint and XFP.MCFD.Scint should be comparable | ||
* Adjust MCFD OBJ threshold looking at scalers. The ratio of OBJ to XFP scaler rates (channels OBJ.MCFD.Scint and XFP.MCFD.Scint) should reflect the transmission of the cocktail beam | * Adjust MCFD OBJ threshold looking at scalers. The ratio of OBJ to XFP scaler rates (channels OBJ.MCFD.Scint and XFP.MCFD.Scint) should reflect the transmission of the cocktail beam | ||
Line 333: | Line 333: | ||
* Probably smaller typical S800 delay needed for HiRA | * Probably smaller typical S800 delay needed for HiRA | ||
* An example of experiments where auxiliary detectors are not used and, thus, setting up coincidence timing is not an issue are the experiments with tritons run by the charge exchange group | * An example of experiments where auxiliary detectors are not used and, thus, setting up coincidence timing is not an issue are the experiments with tritons run by the charge exchange group | ||
- | * It is not clear whether coincidence setup gets logged as “XDT” or “EXR” | + | |
* Choice of setting to be used for coincidence timing setup | * Choice of setting to be used for coincidence timing setup | ||
* The reaction of interest for the experiment can be used to setup coincidences only if the rate of coincidences is high enough | * The reaction of interest for the experiment can be used to setup coincidences only if the rate of coincidences is high enough |