This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
tuning_the_s800_xdt [2015/10/27 07:28] pereira [Object scintillator setup] |
tuning_the_s800_xdt [2015/10/27 13:03] pereira |
||
---|---|---|---|
Line 55: | Line 55: | ||
* Adjust MCFD threshold: | * Adjust MCFD threshold: | ||
- | * Open the [[s800 daq tools# | + | * Using the [[s800 daq tools# |
* The OBJ signal feeding this module is not patched out to data U6 | * The OBJ signal feeding this module is not patched out to data U6 | ||
* The OBJ signal from MCFD module goes to the Mesytec MTDC module and scaler (channel OBJ.MCFD.Scint) | * The OBJ signal from MCFD module goes to the Mesytec MTDC module and scaler (channel OBJ.MCFD.Scint) | ||
Line 286: | Line 286: | ||
| | ||
* The leftmost peak corresponds to reactions with H. The central peak are reaction with C. The goal of the tweak is to make these peaks as narrow as possible | * The leftmost peak corresponds to reactions with H. The central peak are reaction with C. The goal of the tweak is to make these peaks as narrow as possible | ||
- | * Open the NCS application **QtKM** in the Applications Menu. Open file **BLSetup_A1900.gkm**. The magnetic elements that are typically tweaked with the knob box seating | + | * Open the NCS application **QtKM** in the Applications Menu. Open file **BLSetup_A1900.gkm**. The magnetic elements that are typically tweaked with the knob box sitting |
| | ||
* The two figures below show the spectrum **CRDC1.XG!FOI-AFP-BFP** before (top) and after (bottom) the dispersion-matching tuning for a typical experiment. Be aware that the width given by SpecTcl for the selected peak is not too reliable. It is more convenient to do a real gaussian fit. Unfortunatelly this is not an option included in the current version of SpecTcl. That's why some device physicists prefer SpecTk for this type of tuning | * The two figures below show the spectrum **CRDC1.XG!FOI-AFP-BFP** before (top) and after (bottom) the dispersion-matching tuning for a typical experiment. Be aware that the width given by SpecTcl for the selected peak is not too reliable. It is more convenient to do a real gaussian fit. Unfortunatelly this is not an option included in the current version of SpecTcl. That's why some device physicists prefer SpecTk for this type of tuning |