This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
tuning_the_s800_xdt [2015/10/27 16:42] pereira [Send beam to FP] |
tuning_the_s800_xdt [2015/10/27 16:43] pereira [CRDCs setup] |
||
---|---|---|---|
Line 74: | Line 74: | ||
* End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new trigger condition | * End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new trigger condition | ||
- | * Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** | + | * Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** in directory **/ |
* Adjust **[[hv bias|bias]]** looking at 2D spectra **e1.deup_e1.dedown** (showing the parameters s800.fp.e1.de_down vs. s800.fp.e1.de_up) for the FP E1 scintillator | * Adjust **[[hv bias|bias]]** looking at 2D spectra **e1.deup_e1.dedown** (showing the parameters s800.fp.e1.de_down vs. s800.fp.e1.de_up) for the FP E1 scintillator | ||
Line 94: | Line 94: | ||
- | * Select **[[s800 SpecTcl|Spectcl]]** window **S800_IC.win** | + | * Select **[[s800 SpecTcl|Spectcl]]** window **S800_IC.win** |
* Adjust pad gains | * Adjust pad gains | ||
Line 126: | Line 127: | ||
* Count rate is a little higher than on scintillator due to noise or thresholds | * Count rate is a little higher than on scintillator due to noise or thresholds | ||
- | * Check **[[s800 SpecTcl|Spectcl]]** window **S800_CRDCS.win** (see figure below) to verify the good performance of the detectors. (The spectra for each CRDC can be checked separatelly in windows **s800_CRDC1.win** and **S800_CRDC2.win**) | + | * Check **[[s800 SpecTcl|Spectcl]]** window **S800_CRDCS.win** in directory **/ |
* Spectra **crdc1.raws** and **crdc2.raws** (top and middle spectra in the leftmost (first) column) | * Spectra **crdc1.raws** and **crdc2.raws** (top and middle spectra in the leftmost (first) column) |