Line 127: | Line 127: | ||
* Count rate is a little higher than on scintillator due to noise or thresholds | * Count rate is a little higher than on scintillator due to noise or thresholds | ||
- | * Check **[[s800 SpecTcl|Spectcl]]** window **S800_CRDCS.win** (see figure below) to verify the good performance of the detectors. (The spectra for each CRDC can be checked separatelly in windows **s800_CRDC1.win** and **S800_CRDC2.win**) | + | * Check **[[s800 SpecTcl|Spectcl]]** window **S800_CRDCS.win** in directory **/ |
* Spectra **crdc1.raws** and **crdc2.raws** (top and middle spectra in the leftmost (first) column) | * Spectra **crdc1.raws** and **crdc2.raws** (top and middle spectra in the leftmost (first) column) | ||
Line 166: | Line 166: | ||
* The three columns correspond to the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right) | * The three columns correspond to the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right) | ||
* The first (top) row corresponds to the Phillips TDC | * The first (top) row corresponds to the Phillips TDC | ||
- | * The second row corresponds to the MTDC with all the hits included | + | * The second row corresponds to the MTDC with all the hits included. Note that in a unreacted-beam setting, the first hit typically provides the " |
* The third row corresponds to the MTDC with only the first hit | * The third row corresponds to the MTDC with only the first hit | ||
* The fourth row corresponds to the ORTEC TACs. Note that there is not **RF-FP TAC** | * The fourth row corresponds to the ORTEC TACs. Note that there is not **RF-FP TAC** | ||
Line 187: | Line 187: | ||
* Select SpecTcl window **S800_PID.win** in directory **/ | * Select SpecTcl window **S800_PID.win** in directory **/ | ||
* The three columns correspond to the PID determined with the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right) | * The three columns correspond to the PID determined with the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right) | ||
- | * The first (top) row corresponds to the Phillips TDC | + | * The first (top) row corresponds to PID spectra using the Phillips TDC |
- | * The second row corresponds to the MTDC with just the first hit included | + | * The second row corresponds to PID spectra using the MTDC with __just |
- | * The third row corresponds to the ORTEC TACs. Note that there is not **RF-FP TAC** | + | * The third row corresponds to PID spectra using the MTDC gated on the " |
+ | * The fourth row corresponds to PID spectra using the ORTEC TACs. Note that there is not **RF-FP TAC** | ||
* You might need to adjust the limits of the spectra to get a good resolution | * You might need to adjust the limits of the spectra to get a good resolution | ||