User Tools

Site Tools


tuning_the_s800_xdt

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
tuning_the_s800_xdt [2015/10/29 13:21]
pereira [Checking Particle ID and rate at S800 FP]
tuning_the_s800_xdt [2015/10/29 13:25]
pereira [Checking Particle ID and rate at S800 FP]
Line 74: Line 74:
           * End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new trigger condition           * End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new trigger condition
  
-  * Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** in directory **/user/s800/operations/spectcl/Windows**+  * Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** in directory **/user/s800/operations/spectcl/s800v7/Windows**
  
   * Adjust **[[hv bias|bias]]** looking at 2D spectra **e1.deup_e1.dedown** (showing the parameters s800.fp.e1.de_down vs. s800.fp.e1.de_up) for the FP E1 scintillator   * Adjust **[[hv bias|bias]]** looking at 2D spectra **e1.deup_e1.dedown** (showing the parameters s800.fp.e1.de_down vs. s800.fp.e1.de_up) for the FP E1 scintillator
Line 94: Line 94:
  
  
-  * Select **[[s800 SpecTcl|Spectcl]]** window **S800_IC.win** in directory **/user/s800/operations/spectcl/Windows** +  * Select **[[s800 SpecTcl|Spectcl]]** window **S800_IC.win** 
  
   * Adjust pad gains   * Adjust pad gains
Line 127: Line 126:
       * Count rate is a little higher than on scintillator due to noise or thresholds       * Count rate is a little higher than on scintillator due to noise or thresholds
  
-  * Check **[[s800 SpecTcl|Spectcl]]** window **S800_CRDCS.win** in directory **/user/s800/operations/spectcl/Windows** (see figure below) to verify the good performance of the detectors. (The spectra for each CRDC can be checked separatelly in windows **s800_CRDC1.win** and **S800_CRDC2.win**)+  * Check **[[s800 SpecTcl|Spectcl]]** window **S800_CRDCS.win** (see figure below) to verify the good performance of the detectors. (The spectra for each CRDC can be checked separatelly in windows **s800_CRDC1.win** and **S800_CRDC2.win**)
  
       * Spectra **crdc1.raws** and **crdc2.raws** (top and middle spectra in the leftmost (first) column)       * Spectra **crdc1.raws** and **crdc2.raws** (top and middle spectra in the leftmost (first) column)
Line 177: Line 176:
   * Due to the multi-hit capability of the MTDC, we need to select the "good" MTDC ToF peak so that SpecTcl can search for the right hit (more details can be found [[Timing#MTDC|here]]):   * Due to the multi-hit capability of the MTDC, we need to select the "good" MTDC ToF peak so that SpecTcl can search for the right hit (more details can be found [[Timing#MTDC|here]]):
       * Use the spectra **TOF.MTDC_RF**, **TOF.MTDC_OBJ**, and **TOF.MTDC_XFP** (second row in figure above)        * Use the spectra **TOF.MTDC_RF**, **TOF.MTDC_OBJ**, and **TOF.MTDC_XFP** (second row in figure above) 
-      * Using the cursor mouse, check the lower and higher limits defining the region in the MTDC ToF spectra with the "good" ToF peak. Do it of the three ToFs: RF-FP, OBJ-FP, and XFP-FP+      * Using the cursor mouse, check the lower and higher limits defining the region in the MTDC ToF spectra with the "good" ToF peak. Do it for the three ToFs: RF-FP, OBJ-FP, and XFP-FP
       * Go to the **Variables** page in SpecTcl GUI and assign the limits to the following variables:        * Go to the **Variables** page in SpecTcl GUI and assign the limits to the following variables: 
-              * s800.fp.vmetdc.mtdc_objlow and s800.fp.vmetdc.mtdc_rfhigh for RF-XFP +              * **s800.fp.vmetdc.mtdc_objlow** and **s800.fp.vmetdc.mtdc_rfhigh** for RF-XFP 
-              * s800.fp.vmetdc.mtdc_objlow and s800.fp.vmetdc.mtdc_rfhigh for OBJ-XFP +              * **s800.fp.vmetdc.mtdc_objlow** and **s800.fp.vmetdc.mtdc_rfhigh** for OBJ-XFP 
-              * s800.fp.vmetdc.mtdc_xfplow and s800.fp.vmetdc.mtdc_xfphigh for XFP-XFP+              * **s800.fp.vmetdc.mtdc_xfplow** and **s800.fp.vmetdc.mtdc_xfphigh** for XFP-XFP
       * For each ToF, SpecTcl will search the hit number that fits in the selected region. The new MTDC ToF parameters are **s800.fp.vmetdc.mtdc_rf**, **s800.fp.vmetdc.mtdc_obj**, and **s800.fp.vmetdc.mtdc_xfp**        * For each ToF, SpecTcl will search the hit number that fits in the selected region. The new MTDC ToF parameters are **s800.fp.vmetdc.mtdc_rf**, **s800.fp.vmetdc.mtdc_obj**, and **s800.fp.vmetdc.mtdc_xfp** 
  
Line 193: Line 192:
 ==== Checking Particle ID and rate at S800 FP ==== ==== Checking Particle ID and rate at S800 FP ====
  
-  * Select SpecTcl window **S800_PID.win** in directory **/user/s800/operations/spectcl/s800v7/Windows** +  * Select SpecTcl window **S800_PID.win** 
       * The three columns correspond to the PID determined with the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right)       * The three columns correspond to the PID determined with the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right)
       * The first (top) row corresponds to PID spectra using the Phillips TDC       * The first (top) row corresponds to PID spectra using the Phillips TDC