Line 74: Line 74:
           * End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new trigger condition           * End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new trigger condition
  
-  * Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** in directory **/user/s800/operations/spectcl/Windows**+  * Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** in directory **/user/s800/operations/spectcl/s800v7/Windows**
  
   * Adjust **[[hv bias|bias]]** looking at 2D spectra **e1.deup_e1.dedown** (showing the parameters s800.fp.e1.de_down vs. s800.fp.e1.de_up) for the FP E1 scintillator   * Adjust **[[hv bias|bias]]** looking at 2D spectra **e1.deup_e1.dedown** (showing the parameters s800.fp.e1.de_down vs. s800.fp.e1.de_up) for the FP E1 scintillator
Line 94: Line 94:
  
  
-  * Select **[[s800 SpecTcl|Spectcl]]** window **S800_IC.win** in directory **/user/s800/operations/spectcl/Windows** +  * Select **[[s800 SpecTcl|Spectcl]]** window **S800_IC.win** 
  
   * Adjust pad gains   * Adjust pad gains
Line 127: Line 126:
       * Count rate is a little higher than on scintillator due to noise or thresholds       * Count rate is a little higher than on scintillator due to noise or thresholds
  
-  * Check **[[s800 SpecTcl|Spectcl]]** window **S800_CRDCS.win** in directory **/user/s800/operations/spectcl/Windows** (see figure below) to verify the good performance of the detectors. (The spectra for each CRDC can be checked separatelly in windows **s800_CRDC1.win** and **S800_CRDC2.win**)+  * Check **[[s800 SpecTcl|Spectcl]]** window **S800_CRDCS.win** (see figure below) to verify the good performance of the detectors. (The spectra for each CRDC can be checked separatelly in windows **s800_CRDC1.win** and **S800_CRDC2.win**)
  
       * Spectra **crdc1.raws** and **crdc2.raws** (top and middle spectra in the leftmost (first) column)       * Spectra **crdc1.raws** and **crdc2.raws** (top and middle spectra in the leftmost (first) column)
tuning_the_s800_xdt.txt · Last modified: 2023/09/22 15:15 by swartzj