This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
tuning_the_s800_xdt [2015/10/29 13:25] pereira [Ionization Chamber setup] |
tuning_the_s800_xdt [2015/10/29 13:41] pereira [Setting up Reaction Settings] |
||
---|---|---|---|
Line 126: | Line 126: | ||
* Count rate is a little higher than on scintillator due to noise or thresholds | * Count rate is a little higher than on scintillator due to noise or thresholds | ||
- | * Check **[[s800 SpecTcl|Spectcl]]** window **S800_CRDCS.win** in directory **/ | + | * Check **[[s800 SpecTcl|Spectcl]]** window **S800_CRDCS.win** (see figure below) to verify the good performance of the detectors. (The spectra for each CRDC can be checked separatelly in windows **s800_CRDC1.win** and **S800_CRDC2.win**) |
* Spectra **crdc1.raws** and **crdc2.raws** (top and middle spectra in the leftmost (first) column) | * Spectra **crdc1.raws** and **crdc2.raws** (top and middle spectra in the leftmost (first) column) | ||
Line 189: | Line 189: | ||
* Adjust the TDC delays of E1 up, down using the Delay GUI | * Adjust the TDC delays of E1 up, down using the Delay GUI | ||
* In principle, the TACs delays don't need to be adjusted | * In principle, the TACs delays don't need to be adjusted | ||
+ | |||
+ | |||
+ | * Check the efficiencies of the Phillips TDC, TACs, and MTDC for the OBJ-FP and XFP-FP ToFs: | ||
+ | * Make a gate on spectrum **IC.SUM** selecting the region of interest, and call it " | ||
+ | * Looking at the ToF spectra gated on " | ||
+ | * The window file **S800_TOF_EFFICIENCY.win** includes all the spectra needed | ||
+ | |||
==== Checking Particle ID and rate at S800 FP ==== | ==== Checking Particle ID and rate at S800 FP ==== | ||
- | * Select SpecTcl window **S800_PID.win** in directory **/ | + | * Select SpecTcl window **S800_PID.win** |
* The three columns correspond to the PID determined with the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right) | * The three columns correspond to the PID determined with the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right) | ||
* The first (top) row corresponds to PID spectra using the Phillips TDC | * The first (top) row corresponds to PID spectra using the Phillips TDC | ||
Line 329: | Line 336: | ||
* What experimenters want (e.g., if they want singles, the cut has to be more restrictive to limit acquisition deadtime) | * What experimenters want (e.g., if they want singles, the cut has to be more restrictive to limit acquisition deadtime) | ||
* Move blocker, decrease attenuator, repeat | * Move blocker, decrease attenuator, repeat | ||
+ | * If necessary, do the ToF corrections to improve the PID resolution (instructions [[During experiments# | ||