This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
tuning_the_s800_xdt [2015/10/29 13:25] pereira [CRDCs setup] |
tuning_the_s800_xdt [2015/10/29 13:38] pereira [Timing setup] |
||
---|---|---|---|
Line 189: | Line 189: | ||
* Adjust the TDC delays of E1 up, down using the Delay GUI | * Adjust the TDC delays of E1 up, down using the Delay GUI | ||
* In principle, the TACs delays don't need to be adjusted | * In principle, the TACs delays don't need to be adjusted | ||
+ | |||
+ | |||
+ | * Check the efficiencies of the Phillips TDC, TACs, and MTDC for the OBJ-FP and XFP-FP ToFs: | ||
+ | * Make a gate on spectrum **IC.SUM** selecting the region of interest, and call it " | ||
+ | * Looking at the ToF spectra gated on " | ||
+ | * The window file **S800_TOF_EFFICIENCY.win** includes all the spectrum needed. | ||
+ | |||
==== Checking Particle ID and rate at S800 FP ==== | ==== Checking Particle ID and rate at S800 FP ==== | ||
- | * Select SpecTcl window **S800_PID.win** in directory **/ | + | * Select SpecTcl window **S800_PID.win** |
* The three columns correspond to the PID determined with the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right) | * The three columns correspond to the PID determined with the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right) | ||
* The first (top) row corresponds to PID spectra using the Phillips TDC | * The first (top) row corresponds to PID spectra using the Phillips TDC |